IBM 360X (2620) User Manual

Page of 509
     
 
 
Numeric Error Codes
Symptom/Error
FRU/Action
10X
  1. System Board
110
1. Go to “Memory
Checkout” on
page  26.
2. IC DRAM Card
  3. System Board
111
1. Go to “Memory
Checkout” on
page  26.
  2. System Board
161
1. Go to “Checking the
Backup Battery” on
page  31.
  2. Backup Battery
  3. System Board
163
(Time and Date was not
set.)
1. Set Time and Date.
  2. System Board
173
(Configuration data were
lost.)
1. Select OK in the error
screen; then set time
and date.
  2. Backup Battery
  3. System Board
174
(Perform “Checking the
Installed Devices List” on
page 46 before changing
any FRUs.)
  1. Check Device
Configuration.
  2. System Board
  3. Diskette Drive
Assembly
4. Hard Disk Drive
Assembly
184
(POP check sum error.)
1. Reset the POP in
Easy-Setup.
190
(A depleted battery pack
was installed when the
power was on.)
1. Go to “Checking the
Battery Pack” on
page  30.
191XX
  1. System Board
199XX
  1. System Board
1XX
  1. System Board
2XX
1. Go to “Memory
Checkout” on
page  26.
2. IC DRAM Card
  3. System Board
   
ThinkPad 340x (IBM 2610)