IBM 1400 (2611) User Manual

Page of 204
      
 
 Indicator-Related Symptoms
Symptom/Error
FRU/Action in Sequence
Indicator incorrectly
remains off or on, but
system runs cor-
rectly.
Ÿ
Reconnect the indicator board
connector.
 
Ÿ
Indicator board
 Power-Related Symptoms
Symptom/Error
FRU/Action in Sequence
Power shuts down
during operation.
Ÿ
Go to “Power Systems
Check” on page 111.
 
Ÿ
AC Adapter
 
Ÿ
Battery pack
 
Ÿ
Audio PCB
 
Ÿ
DC/DC charger
 
Ÿ
System board
The system doesn't
power on.
Ÿ
Go to “Power Systems
Check” on page 111.
 
Ÿ
AC Adapter
 
Ÿ
DC/DC charger
 
Ÿ
System board
The system doesn't
power off.
Ÿ
Go to “Power Systems
Check” on page 111.
Ÿ
Hold and press the power
switch for more than 4
seconds.
 
Ÿ
DC/DC charger
 
Ÿ
System board
Battery can't be
charged.
Ÿ
Go to “Power Systems
Check” on page 111.
 
Ÿ
Battery pack
 
Ÿ
DC/DC charger
 
Ÿ
System board
 Memory-Related Symptoms
Symptom/Error
FRU/Action in Sequence
Memory count (size)
appears different
from the actual size.
Ÿ
Go to “Memory Check” on
page  113.
Ÿ
Enter BIOS Utility and
execute "Load Setup Default
Settings"; then reboot the
system.
 
Ÿ
DIMM
 
Ÿ
System board
128
ThinkPad i Series 1400 HMM