Brocade Communications Systems 825 User Manual

Page of 228
Brocade Adapters Administrator’s Guide
165
53-1001256-01
diag
B
diag 
Lists the non-destructive group of diagnostic commands.
Synopsis
bcu diag --sfpshow <port_id
bcu diag --tempshow [ad_id
bcu diag --beacon <port_id> {on | off} [-t <secs>] 
bcu diag --pciloopback <port_id> <pattern
bcu diag --loopback <port_id> [-t <sub_test_id>] [-s <speed>] [-c <count>] 
[-p <pattern>] 
bcu diag --memtest <port_id
bcu diag --queuetest <port_id>
Description
Displays the group of diagnostic commands that are non-destructive and indicates when the 
adapter is running at a normal operation state.
NOTE
You must disable the port prior to executing the loopback test. You must disable the adapter prior to 
executing the memtest.
Operands
--sfpshow
Monitors the attributes of the SFP. This is an online diagnostic test. 
Note: A notification occurs for any parameter that is not within the configured 
power, temperature, and voltage policies.
port_id
Specifies the ID of the port on which you want to monitor the SFP attributes.
--tempshow
Reads the adapter’s temperature sensor registers. This is an online 
diagnostic test.
ad_id
Specifies the ID of the adapter for which you want to display temperature 
sensor registers. Values include below the minimum, normal, above the 
maximum, and sensor fault.
--beacon
Controls the port and link end-to-end beaconing. This is an online diagnostic 
test.
port_id
Specifies the ID of the port for which you want to beacon.
on | off
Turns end-to-end beaconing on or off.
-t secs
Displays the beacon time duration in seconds. Beaconing is automatically 
turned off after the specified duration. If the duration is set to 0, beaconing 
continues until it is explicitly turned off.
--pciloopback
Sends a health check message from the host to firmware through message 
queues memory mapped over the PCI. This is an online diagnostic test.
port_id
Specifies the ID of the port for which you want to send a health check 
message.
pattern
Displays the data pattern.