Symptom/Error
FRU/Action
2XX
1. Go to “Memory
Checkout” on
page  317.
2. IC DRAM Card, DIMM,
or DIMM Adapter
  3. System Board
301, 303, 304, 305, 3XX
  1. Go to
“Keyboard/Auxiliary
Input Device
Checkout” on
page  320.
  2. Keyboard
  3. Video Card
  4. External Numeric
Keypad
  5. External Keyboard
  6. Keyboard/Mouse Cable
  7. System Board
601, 6XX
1. Go to “Diskette Drive
Test” on page 321.
  2. Diskette Drive
Assembly
  3. Diskette
  4. System Board
602
(Diskette read error.)
1. Go to “Diskette Drive
Test” on page 321.
  2. Diskette
  3. Diskette Drive
Assembly
604
(Non-acceptable ID was
read from the diskette
drive.)
1. Go to “Diskette Drive
Test” on page 321.
  2. Diskette Drive
Assembly
  3. System Board
11XX
1. Serial Device (First)
  2. Communication Cable
  3. System Board
12XX
  1. Serial Device
(Second)
  2. Communication Cable
  3. System Board
17XX
1. Hard Disk Drive
  2. System Board
24XX
  1. System Board
  2. Video Card
808X
  1. PCMCIA Slot
Assembly
  2. PCMCIA Device
  3. System Board
860X
(Pointing device error when
TrackPoint III is disabled.)
  1. External Mouse
  2. External Keyboard
  3. System Board
   
ThinkPad 755CD, 755CDV (9545)
333