IBM 1419 User Manual

Page of 91
 Symptom-to-FRU Index
The Symptom-to-FRU Index lists the symptoms and errors
and the possible causes. The most likely cause is listed
first.
Note:  Perform the FRU replacement or actions in the
sequence shown in the FRU/Action columns. If a
FRU does not solve the problem, put the original
part back in the computer. Do not replace a non-
defective FRU.
This index can also be used to help you decide which
FRUs should be available when servicing a computer.
Numeric error codes show the errors detected in POST or
system operation (runtime). In the following error codes, X
can be any number.
If no codes are available, use narrative symptoms.
If the symptom, is not listed, go to “Undetermined
Problems” on page 25.
Note:  For any IBM device not supported by the diagnostic
codes in this ThinkPad computer, see the manual
for that device.
Numeric Error Codes and Messages
Error
Code
Message
FRU/Action in Sequence
POST
010
Memory Error
at MMMM:
SSSS:
OOOOh
(R:xxxxh,
W:xxxxh)
Ÿ
Go to “Memory Check”
on page 8.
 
Ÿ
DIMM
 
Ÿ
Planar board
040
Diskette Drive
Controller
Error
Ÿ
Go to “Diskette Drive
Check” on page 11.
Ÿ
Ensure the diskette
drive configuration
setting in BIOS Utility
is correct.
Ÿ
Diskette drive cable
 
Ÿ
Diskette drive
 
Ÿ
Planar board
047
Diskette
Drive(s) Disa-
bled
Ÿ
Ensure the diskette
drive is not set to "Dis-
abled" in the "System
Security" menu of the
BIOS Utility.
Ÿ
Diskette drive cable
 
Ÿ
Diskette drive
   
ThinkPad i Series 1400
17