Crestron electronic TPS-12G-QM User Manual

Page of 70
Crestron TPS-12G/15G/17G-QM Isys
®
 G-Series Touchpanels
 
NOTE:  There is both an Ethernet device in Slot 8 and a Cresnet device in Slot 9 of 
the following illustration. It is possible to have both types of device attached to a 
control system so long as the control system has either a built-in or expansion 
Ethernet interface. 
C2Net Device, Slot 8 and 9 
 
•  Additional TPS-12G/15G/17G-QM devices are assigned different Net ID 
(for Cresnet devices) or IP ID (for Ethernet devices) numbers as they are 
added. 
•  If necessary, double click a device to open the “Device Settings” window 
and change the Net ID or IP ID), as shown in the following figure. 
“TPS-17G-QM (Cresnet) Device Settings” Window  
(Same as window for TPS-12G-QM and TPS-15G-QM) 
 
Operations Guide – DOC. 6415B 
Isys
®
 G-Series Touchpanels: TPS-12G/15G/17G-QM  
  51