Installation (Continued)
2.  If repair or replacement of cord or 
plug is necessary, do not connect 
grounding wire to either flat blade 
terminal. The wire with insulation 
having an external surface that 
is green (with or without yellow 
stripes) is the grounding wire.
 
Never connect 
  green (or green and 
yellow) wire to a live terminal.
3.  Check with a qualified electrician or 
serviceman if grounding instructions 
are not completely understood, or 
if in doubt as to whether product is 
properly grounded. Do not modify 
plug provided; if it will not fit outlet, 
have proper outlet installed by a 
qualified electrician.
 
Overheating, short 
  circuiting and fire 
damage will result from inadequate 
wiring, etc.
Operation
DeFInItIOn OF terMS
On / OFF Switch ( I / O ) 
- Push 
switch to the ON ( I ) position to turn 
compressor on. Push switch to the 
OFF ( O ) position to turn compressor 
off. This switch should be in the 
OFF ( O ) position when connecting 
/ disconnecting power cord from 
electrical outlet or when changing tools.
ON Position
OFF Position
Figure 3 
Pressure Switch (located internally)
When the compressor is turned ON, 
this switch will shut compressor off 
automatically when tank pressure 
reaches maximum shut-off / cut-out 
pressure. If compressor remains on and 
air is depleted from tank, this switch 
will allow compressor to automatically 
restart at the restart / cut-in pressure.
regulator - The regulator controls the 
amount of air pressure released at the 
hose outlet. Turning the regulator knob 
clockwise (to the right) will increase air 
pressure at the outlet. Turning the knob 
counter-clockwise (to the left) will lower 
air pressure to the outlet. Turning knob 
fully counter-clockwise will shut off flow 
of air completely.
Pressure Gauges - There are two 
gauges located next to the regulator. 
These gauges read air pressure in 
pounds per square inch (psi) The larger 
gauge shows pressure at the outlet. 
Make sure this gauge reads ZERO 
(by adjusting the regulator) BEFORE 
changing air tools or disconnecting 
hose from outlet. The small gauge 
shows pressure in the tank indicating 
compressor is building pressure 
properly. 
aSMe Safety Valve - This valve 
automatically releases air if the tank 
pressure exceeds the preset maximum.
handle - Designed to move the 
compressor.
Motor reset - (not shown, located 
inside motor). Designed to keep the 
motor from overheating. The motor has 
an auto reset protector. To reset once 
the motor has cooled, turn the switch 
to the OFF position, then to the ON 
position.
Drain Valve - This valve is located on 
the bottom of the tank. Use this valve 
to drain moisture from the tank daily to 
reduce the risk of corrosion.
Figure 4
lUbrICatIOn
This is an oilless product and DOeS nOt 
require lubrication to operate.
beFOre FIrSt Start-UP           
break-In PrOCeDUre
(Complete this procedure before using 
compressor for the first time. Once 
completed, it is not necessary to repeat.)
1.  Turn regulator knob fully clockwise 
(to the right) to open air flow.
2.  Do not attach a hose or any other 
fitting to the compressor.
3.  Turn on/off switch to OFF position.
4.  Plug in power cord.
5.  Turn on/off switch to ON position. 
Allow compressor to run for 5 
minutes.
6.  Turn on/off switch to OFF position.
7.  Unplug power cord.
beFOre eaCh Start-UP    
OPeratInG PrOCeDUre 
1.  Turn switch to OFF ( O ) position and 
plug in power cord.
2.  Turn regulator knob 
counterclockwise to close air flow.
3.  Turn switch to ON ( I ) position.
4.  Compressor will build to maximum 
pressure and shut off.
5.  With hose attached to outlet of 
compressor, attach tire chuck or 
other tool to open end of hose.
Figure 2 - Unit Identification
Pressure 
Gauge
ON/OFF Switch
Safety Valve
Drain Valve
Air Outlet
Handle
Regulator
Knob