Heatilator • WHB/WTB Refractory • 4055-186 Rev C • 03/08
2
1.  Shut off the electricity to the appliance and turn the gas 
shutoff valve to the closed position. See Figure 1. Remove 
the screen and glass from the appliance.
Figure 1 - Gas Shutoff Valve
2.  If installing this refractory into a B-Vent Appliance, please 
go to “To Convert Refractory Kit to Fit B-Vent Appliance” 
on page 4 of this manual.
3.  Attach the two long hook-shaped brackets by removing 
the two outside screws on the false back and reinstall the 
screws. See Figures 2 and 3. 
 
Make sure to shorten the bracket if installing in a B-vent 
unit. See Figure 4.
Figure 2 
Location of Hook-Shaped Brackets
Figure 3 
Loosen Brackets
Figure 4 
Shorten Brackets for B-Vent Installation
4.  Set the back refractory piece into the brackets. See 
Figures 5 and 6.
Figure 5 
Position Back Refractory for Placement
Figure 6 
Set Back Refractory in Place