Operation
1.  Start the heater per instructions and allow it to warm 
up. 
2.  Turn the wall switch "ON" to start air fl ow at the air duct 
register or use RC300 remote to turn on blower.
Maintenance
1.  Service and maintain the gas heater per instructions.
2.  Keep the air register(s) clean and free of any blockage. 
3.  Reference IPI Plus instructions with remote control for 
fan auxiliary control.
STUD
BROWN HOT 
BROWN 
BLUE NEUTRAL
BLUE
YELLOW / GREEN
GROUND
GROUND
SWITCH 
JUNCTION BOX
FAN
JUNCTION BOX
FAN
BLUE
BROWN
AUX1= 3 FAN SPEEDS
AUX2= ON/OFF CONTROL HIGH ONLY
GREEN/
YELLOW
BROWN
BLUE
GREEN/YELLOW
BLUE
WHITE
FAN
BROWN
BLACK
AUX1
AUX2
FAN
JUNCTION BOX 
2166-191 JUMPER
APPLIANCE
JUNCTION BOX 
BLUE
BROWN
GREEN/
YELLOW
JUNCTION BOX AND 
CONNECTION WIRE SUPPLIED 
BY INSTALLATION 
PROFESSIONAL
FAN HOUSING
ADAPTER FRAME
1/2 in.
(13 mm)
REGISTER
Isolated ON/OFF control wall switch
IPI Plus with auxiliary control