Hearth & Home Technologies MBK User Manual

Page of 32
R
Page 2
   7004-187F  September 1, 2008
Yosemite Wood Stove
and Welcome to the Quadra-Fire Family
!
H
earth & Home Technologies welcomes you to our tradition of 
excellence!  In choosing a Quadra-Fire appliance, you have our 
assurance of commitment to quality, durability, and performance.
This commitment begins with our research of the market, including 
‘Voice of the Customer’ contacts, ensuring we make products that 
will satisfy your needs. Our Research and Development facility 
then employs the world’s most advanced technology to achieve 
the optimum operation of our stoves, inserts and fireplaces.  And 
yet we are old-fashioned when it comes to craftsmanship.  Each 
unit is meticulously fabricated and gold and nickel surfaces are 
hand-finished for lasting beauty and enjoyment.  Our pledge to 
quality is completed as each model undergoes a quality control 
inspection.    
We wish you and your family many years of enjoyment in the 
warmth and comfort of your hearth appliance.  Thank you for 
choosing Quadra-Fire.
LABEL IS LOCATED ON THE BACK OF THE STOVE
Serial Number
Model Name
Testing Lab &
Report Number
VENT SPECIFICATIONS:
SINGLE WALL: 
Six inch (6") (152mm) diameter, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built UL103 
HT Class "A" chimney, suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
DOUBLE WALL: 
Six inch (6") (152mm) diameter, listed double wall air insulated connector pipe with listed factory-built UL103 HT Class 
"A" chimney, or  a masonry chimney and the referenced clearances.
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree Factory-built chimneys.
MOBILE HOME:  
Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DL double wall connector pipe. Must be 
equipped with a spark arrestor.  Apply double wall clearances below when installing unit.
DO NOT REMOVE THIS LABEL 
Made in U.S.A.
LISTED ROOM HEATER, SOLID FUEL TYPE.   ALSO FOR USE IN MOBILE 
HOMES.  (UM) 84-HUD . 
"For Use with Solid Wood Fuel Only" 
Install and use only in accordance with manufacturer's 
installation and operating instructions.  Contact local building or 
fire officials about restrictions and installation inspections in 
your area. Do not obstruct the space beneath heater.
WARNING - For Mobile Homes:    Do not install in a sleeping 
room.  An outside combustion air inlet must be provided and 
unrestricted while unit is in use.  The structural integrity of the 
mobile home floor, ceiling and walls must be maintained.  The 
stove needs to be properly grounded to the frame of the mobile 
home.  Components required for mobile home installation:  
Outside Air Kit, Part Number 831-1780.
Refer to manufacturer's instructions and local codes for 
precautions required for passing chimney through a 
combustible wall or ceiling and maximum offsets.
Inspect and clean chimney frequently - Under Certain Conditions of 
Use, Creosote Buildup May Occur Rapidly.
Do not connect this unit to a chimney serving another 
appliance.
Optional Components:  Optional Blower, Part 831-1701.
Electrical Rating:  115 VAC, 1.2 Amps, 60 Hz.
Route power cord away from unit.  Do not route cord under or 
in front of appliance.
DANGER: Risk of electrical shock.  Disconnect power supply 
before servicing.
Replace glass only with 5mm ceramic available from your dealer.
Do not use grate or elevate fire.  Build wood fire directly on 
firebrick.
Do not overfire - if heater or chimney connector glows, you are 
overfiring.
Operate only with the fuel loading door closed.  Open only to 
add fuel to the fire.
U.S. ENVIRONMENTAL PROTECTION AGENCY -
Certified to comply with July 1990 particulate emission 
standards.
PREVENT HOUSE FIRES
FLOOR PROTECTION*:
Floor protector must be 
non-combustible material or 
equivalent, extending beneath 
heater and to front/sides/rear as 
indicated on the diagram. 
 
Exception: Non-combustible floor 
protections must extend beneath 
the flue pipe when installed with 
horizontal venting and extend 2" 
(51mm) beyond each side. 
O-T L
Tested and Listed 
by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
Report:  #061-S-54-2
TESTED TO:
  UL 1482, UL737, ULC S627. 
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN 
BURNS.  KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE 
NAMEPLATE AND INSTRUCTIONS.
SERIAL NO.
YOSEMITE
R
7004-188
www.quadrafire.com
Mfg by
Minimum 16"
 
(406mm) 
from 
fuel loading
 
door
8"
(203mm)
USA
44-1/2
"
(1130mm) Minimum
36-11/16
"
(932mm)
Minimum
 Fuel loading doors
Front
Side
Both fuel loading doors accessible
8"
(203mm)
16"
 
(406mm) 
from fuel 
loading door
8"
(203mm)
USA
Front Fuel 
loading door
33"
(838mm) Minimum
36-11/16
"
(932mm)
Minimum
Side fuel loading door locked shut
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
NOTE:  All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
G
H
E1
E2
F1
F2
Fuel door 
side
Non-fuel 
door side
SEE MANUAL FOR OTHER CONFIGURATIONS
*In Canada: Must be minimum 18"(450mm) in front of both fuel loading 
doors and 8" (200mm) on both sides and back.
**NFPA MINIMUM CLEARANCE - NOT TESTED
B
A
C1
Non-fuel 
door side
D2
Fuel Door 
side
C2
D1
US Patents 4,766,876; 5,113,843; 5,341,794
CAUTION:
SAMPLE
TOP VENT VERTICAL
A
B
 C1
C2*
D1
D2*
E1
E2*
F1
F2*
G
H
Single Wall-USA
12.5(316) 9(229) 19.5(495) 25.5(648) 10(254) 16 (406) 14(356) 16(406) 18.5(470) 20.5(521)
59(1499) N/A
Single Wall-Canada
12.5(316) 9(229) 19.5(495) 27.5(669) 10(254) 18 (457) 14(356) 18(457) 18.5(470) 22.5(572) 59(1499) N/A
Double Wall- USA
10.5(267) 7(178) 19.5(495) 25.5(648) 10(254) 16(406) 7 (178) 16(406) 11.5(292) 20.5(521) 59(1499) N/A
Double Wall-Canada
1
0.5(267) 7(178) 19.5(495) 27.5(699) 10(254) 18(457) 7 (178) 18(457) 11.5(292) 22.5(572)
59(1499) N/A
HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP
Single Wall-USA
13.5(343) 10(254) 19.5(495) 25.5(648) 10(254) 16 (406)
N/A
N/A
N/A
N/A
59(1499) 18**
Single Wall-Canada
13.5(343) 10(254) 19.5(495) 27.5(699) 10(254) 18 (457)
N/A
N/A
N/A
N/A
59(1499) 18**
Double Wall-USA
11.5(330) 8(203) 19.5(495) 25.5(648) 10(254) 16(406)
N/A
N/A
N/A
N/A
59(1499) 18**
Double Wall-Canada
11.5(330) 8(203) 19.5(495) 27.5(699) 10(254) 18(457)
N/A
N/A
N/A
N/A
59(1499) 18**
     2008     2009    2010     Jan.      Feb.     Mar.     Apr.     May     June    July      Aug.    Sept.     Oct.  Nov.      Dec.
007
US
1445 N. Highway, Colville, WA 99114
Serial Number