1. Remove  the  appliance  and  surround  panels  from  the  packaging;  check  to  make  sure  there  is  no 
damage. Carefully check the glass door. Do not use the unit if it is damaged. In the event damage is 
found, please report it to both the courier and your dealer as soon as possible. 
2. Carefully clean the fireplace and flue before installing the stove. Failure to do so may result in fumes 
or dirt being blown into the room and may cause a fire leading to death or serious injury.
3. Remove the glass door; see M
AINTENANCE
 A
ND
 S
ERVICE
 - G
LASS
 D
OOR
 R
EMOVAL
.
4. Remove log and ember set and all wrapping material from inside the stove. Remove wrapping material 
from log and embers and check for any damage. If damage is observed, do not use unit and contact 
your local dealer.
5. Remove the vent collar plate from the top of the stove by unscrewing the two (2) T-20 Torx screws 
located on the center  top of the stove. Slide collar plate backwards. Properly secure the vent collar 
plate to the flexible vent pipe liner(s) previously installed in the chimney. Be careful not to over-stretch 
the liner(s).
Initial Installation
QUALIFIED INSTALLERS ONLY
D
IRECT
 V
ENT
 M
ODEL
:
WARNING: This appliance has been designed to draw room air for proper heat circulation 
from the sides of the unit.  Blocking or modifying the louvers in any way can create hazardous 
situations.
This model is vented with TWO (2) 3” aluminum or stainless steel flex vent leading into a co-linear to co-
axial vent adaptor and using a Simpson Dura Vent vertical termination cap. The flue collars of this model 
will fit inside of standard 3” vent and may be fastened directly to the vent. The Exhaust vent is in the 
center of the flue connector. The Air Intake is on the left side of the vent collar plate (this outlet is not in 
the center it is off to one side of the vent collar plate.)
Check  periodically  that  the  vents  are  unrestricted.  Also  ensure  that  all  direct  vent  pipes  have  been 
properly sealed and installed after routine inspection or cleaning. The air intake and exhaust pipes must 
be installed in the correct locations on the removable draft hood connector.
D
IRECT
 V
ENT
 R
ESTRICTOR
 R
ING
:
Figure 14: Direct vent restrictor ring installation.
Vent Restrictor Ring
DIRECT  VENT  ONLY:  The  maximum  vertical  vent 
height for a direct vent installation is 25 feet (7.62 m). 
Use  the  vent  restrictor  ring  for  installations  above  15 
feet (4.57 m). See Figure 14 for installation of restrictor 
ring.
13