PLACEMENT IN A FIREPLACE wITh A RESTRICTIvE BARRIER 
IMPORTANT INFORMATION FOR ThE INSTALLATION OF ThIS GAS LOG SET
The following are guidelines for placing a gas log set in a fireplace that has a restrictive barrier along the bottom 
front opening of the fireplace. Some examples of barriers are glass/screen door frames and sunken/recessed 
fireplaces.
Glass door frames 
with adjustable louvers 
should have the louvers
 
fully open while the unit 
is in operation. 
Height of restrictive barrier caused 
by  glass  door  frames,  recessed 
fireplaces,  etc.  from  the  base  or 
bottom surface of the unit. (refer
to table).
The log set should be placed against 
or as near as possible to the rear wall 
of the fireplace/firebox. 
Depth of fireplace/firebox. 
(refer to table).
Figure 3 - Reference Drawing of the MJ27 Log Set in an Enclosure 
NOTE: Noncombustible material such as refractory brick may be used to line the floor of the fireplace 
in order to raise the height of the gas log set in relation to a restrictive barrier. If the unit is raised, the 
minimum height dimension listed in the homeowner’s manual must not be exceeded.
NOTE: If the log set is equipped with a remote receiver, a restrictive barrier may reduce the battery life by 
increasing the ambient temperature inside the fireplace. Placement of the receiver outside of the fireplace 
will extend the battery life. 
Height of Restriction (X)
Minimum Depth of Fireplace/Firebox
No restriction
14"
0 to 1
1
/
2
"
17"
From 1
1
/
2
" to 3"
17"
Greater than 3"
ANY BARRIER GREATER THAN THREE INCHES (3") PLACED IN FRONT OF 
THE GAS LOG SET IS NOT RECOMMENDED BY THE MANUFACTURER.
Barriers such as the bottom of a glass door frame placed in front of a gas log set can 
change the air flow characteristics of the fireplace which in turn can cause the unit to 
overheat and malfunction. 