Monessen Hearth MJ27NR User Manual

Page of 40
20 
86D0024
FP2008
gas valve
FP2008
ChECkING GAS PRESSuRE
The heater gas inlet connection is a 3/8" NPT at the valve. 
On all control type units, the inlet connection is on the right 
side of unit. To connect from the opposite side, route the pipe 
around the back portion of the unit.
When  tightening  up  the  joint  to  the  valve,  hold  the  valve 
securely to prevent movement. 
MILLIVOLT  VALVE CONTROL (Figure 15)
The valve regulator controls the burner pressure 
which  should  be  checked  at  the  pressure  test 
point.
Turn captured screw counter clockwise two or three 
turns and then place tubing to pressure gauge over 
test point (Use test point “OUT” closest to control 
knob). After taking pressure reading, be sure and 
turn captured screw clockwise firmly to re-seal. Do 
not over torque. Check for gas leaks.
Test all gas joints from the gas meter to the heater valve for leaks using a gas analyzer or soap and water solu-
tion after completing connection. 
DO NOT uSE AN OPEN FLAME.
Check the gas pressure with the appliance burning and the control set to 
HIGH.
W
ARNING
Connecting  directly  to  an 
unregulated  propane/LPG  tank 
can cause an explosion.
Figure 15 - Pressure Test Point Location
Millivolt Control 
Test Port “OUT”