Monessen Hearth MJ27NR User Manual

Page of 40
86D0024
29
LG551 
MJ log flames 
LG551
In normal operation at full rate after 15 minutes, the following flame appearances 
should be observed:
Figure 33 - Correct Burner Flame Appearance
Burner will have a random pattern of yellow flames as shown in Figure 33. There should be glow-
ing embers on the front burner. Note: The front flames and embers will be an opaque orange 
color during the burn off time. 
OPERATING INSTRuCTIONS
Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into the 
fireplace. Do not place a blower inside the burn area of the firebox. Ceiling fans may create drafts 
that alter flame patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are treated 
with certain oils, films or bonding agents. These chemicals are not harmful, but may produce 
annoying smoke and smells as they are burned off during the initial operation of the appliance, 
possibly causing headaches or eye or lung irritation. this is a normal and temporary occurrence.
The initial break-in operation should last four hours with the burner at the highest setting. Provide 
maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remain-
ing after this initial break-in will be slight and will disappear with continued use.
This appliance must not be used with glass doors in the closed position. This can lead to pilot out-
ages and severe sooting outside the fireplace. refer to Page 10, Figure 3.
CHECKING THE BURNER FLAME