Monessen Hearth MJ27NR User Manual

Page of 40
86D0024
PRODuCT FEATuRES and SPECIFICATIONS
NATURAL GAS
NOTE: An external regulator is required to reduce supply pressure to a maxi-
mum of 10 
1
/
2
" W.C. on natural gas systems operating at higher pressure.
 
MILLIVOLT
Regulator Pressure Setting:  3.5" w.c.
Pilot Regulator:  
3.5" w.c.
Gas Inlet Pressure:  
Max 10
1
/
2
" w.c.
 
Min. 5" w.c.
PROPANE/LPG
Note: An  external  regulator  is  required  to  reduce  supply  pressure  to  a 
maximum of 13" w.c.
MILLIVOLT
Regulator Pressure Setting:   10" w.c 
Gas Inlet Pressure:  
Max. 13" w.c.
 
Min. 11" w.c.
IGNITION CONTROLS 
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
  Millivolt control has three (3) positions:
 
OFF 
  -  All gas to the gas logs is shut off at the valve.
 
IGN 
  -  Valve position to light/maintain a standing pilot.
 
ON 
  -  Valve position to turn ON/OFF log set with remote switch/thermostat.
PILOT/ODS
The gas log heater is fitted with a specially designed safety pilot (ODS assembly) which 
senses the amount of oxygen available in the room and shuts the gas log heater off if the 
oxygen level begins to drop below a satisfactory level. The pilot can only be relit when 
adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a Millivolt (thermopile) generator to provide power 
for remote activation.
 
 
 
 
Gas Rate
  Model Number  Control  Max. BTu/hr    Min. BTu/hr
 
MJ27NR 
Millivolt 
38,000 
 
25,500
 
 
 
 
Gas Rate
  Model Number  Control  Max. BTu/hr    Min. BTu/hr
 
MJ27PR 
Millivolt 
37,000 
 
29,500