     WARNING 
 
 
 
Do not clean glass when hot. 
Do not clean glass with abrasive cleaners. 
  Care and Maintenance  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Over time combustion products may leave a film on 
the combustion chamber glass.  Continued use of the 
appliance may permanently stain the glass.  If filming 
occurs, this glass panel needs to be removed, 
cleaned, and installed only by a qualified service 
technician. 
Cleaning Combustion Chamber Glass
 
1.  Open the side louvers and on each side remove 
one screw  attaching the top panel.  (Side louvers 
are opened by pushing in and releasing.) 
2.  Remove two screws attaching the front panel to 
the appliance. 
3.  Remove the front panel by rotating the bottom 
away from the appliance and lifting upwards to 
unhook the panel from the top of the appliance. 
4.  Remove two retaining screws and remove the 
combustion chamber glass panel.   
5.  Clean using non-abrasive, non-solvent household 
cleaner. 
6.  Install the glass panel.  Refer to Final Assembly. 
7.  Install the front panel with two screws through the 
louvers.  Refer to Final Assembly. 
8.  Install the top panel with one screw on each side 
of the side louvers.  Refer to Final Assembly. 
CORRECT PILOT FLAME APPEARANCE 
The pilot flame should be blue and extend over the 
flame rod from half to three-fourths of its length.  It 
should not be long, streaky, or yellow. 
Clean exterior as required using non-abrasive and 
non-solvent cleaner.  Ensure exterior is completely 
dry before operating. 
Care of Exterior
 
rotate
outward
 first
unhook top
Front Panel