Gas Information
A.  Fuel Conversions
Before making gas connections ensure that the appliance 
being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to meet 
the appliance and locality needs must be made by a quali-
fied technician using Hearth & Home Technologies specified 
and approved parts.
1. Converting to LP Gas
Figure 6.2
   Remove the burner support by loosening the left 
screw on the pilot tower, and removing the two screws on 
the front side of the burner neck support. 
KIT CONTENTS:  Replacement orifice; replacement 
pilot injector; valve regulator; and conversion label.
TOOLS REQUIRED:  Power drill (a 90° handle is help-
ful); #2 Phillips bit; 5/32" Allen wrench; 5/8" open end 
wrench.
Figure 6.3
    Slide the burner neck support to the left. Pull off 
pilot hood and set aside.
NOTE: Gas conversions should only be performed 
by a qualified service person, and/or where required 
by state and local codes, licensed installer/service 
technician. In the Commonwealth of Massachusetts, 
installation must be performed by a licensed plumber 
or gas fitter.
IMPORTANT NOTE! The orifice supplied with this con-
version kit is for TOP VENT MODELS ONLY.  If your stove 
was fitted with the rear vent kit, the correct conversion 
orifice was supplied WITH THE REAR VENT KIT. 
Figure 6.1
   Remove front (if installed), glass, and logs (if 
installed.) Using the #2 Phillips screwdriver remove the two 
(2) 1/4" x 20 screws securing the burner as indicated. Lift 
burner out of firebox.
Figure 6.4
    Use a 5/32" Allen wrench to remove the pilot 
injector.