Hearth & Home Technologies SAPPH-D-CSB User Manual

Page of 56
         September 1, 2008
Page  41
Quadra-Fire · Sapphire · 250-7233H
10
Troubleshooting
With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do 
experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the 
corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.
Symptom
Possible Cause
Corrective Action
1.  After repeated trig-
gering of the piezo 
button, the spark ignitor 
will not light the pilot.
a.  Defective ignitor.
Check the spark at the electrode and pilot. If no spark and electrode 
wire is properly connected, replace the ignitor.
b.  Defective pilot or 
misaligned electrode 
(spark at electrode).
Using a match, light the pilot. If the pilot lights, turn off the pilot and trig-
ger the piezo button again. If the pilot lights, an improper gas/air mixture 
caused the bad lighting and a longer purge period is recommended. If 
the pilot will not light, ensure the gap at the electrode and pilot is one-
eighth (1/8) inch to have a strong spark. If the gas is OK, replace the 
pilot.
c.  No gas or low gas 
pressure.
Check the remote shut-off valve from the appliance. Usually, there is a 
valve near the gas main. There can be more that one (1) valve from the 
appliance and the main.
d.  No LP in tank.
Check the LP (propane) tank. You may be out of fuel.
2.  The pilot will not stay 
lit after carefully follow-
ing the lighting instruc-
tions.
a.  Defective thermo-
couple.
Check that the pilot flame impinges on the thermocouple. Clean and /or 
adjust the pilot for maximum flame impingement.
Ensure that the thermocouple connection at the gas valve is fully 
inserted and tight (hand tighten plus 1/4 turn).
Disconnect the thermocouple from the valve, place one millivolt lead 
wire on the tip of the thermocouple and the other meter wire on the ther-
mocouple copper lead. Start the pilot and hold the valve knob in. If the 
millivolt reading is less than 15mV, replace the thermocouple.
b.  Defective valve.
If the thermocouple is producing more than 15 millivolts, replace faulty 
valve.
3.  The pilot is burning, 
there is no gas to the 
burner, the valve knob is 
in the ON position, and 
the ON/OFF switch is in 
the ON position.
a.  ON/OFF switch or 
wires defective.
Check the ON/OFF switch and wires for proper connections. Place the 
jumper wires across the terminals at the switch. If the burner comes on, 
replace the defective switch. If the switch is OK, place the jumper wires 
across the switch wires at the gas valve. IF the burner comes on, the 
wires are faulty or connections are bad.
b.  Thermopile may 
not be generating 
sufficient millivoltage.
If the pilot flame is not close enough physically to the thermopile, adjust 
the pilot flame.
Be sure the wire connections from the thermopile at the gas valve ter-
minals are tight and that the thermopile is fully inserted into the pilot 
bracket. 
Check the thermopile with a millivolt meter. Take the reading at TH-
TP&TP terminals of the gas valve. The meter should read 325 millivolts 
minimum, while holding the valve knob depressed in the pilot position, 
with the pilot lit, and the ON/OFF switch in the OFF position. Replace 
the faulty thermopile if the reading is below the specified minimum.
With the pilot in the ON position, disconnect the thermopile leads from 
the valve. Take a reading at the thermopile leads. The reading should 
be 325 millivolts minimum. Replace the thermopile if the reading is 
below the minimum.