Gianni Industries 982-10 User Manual

Page of 4
 
Copyright All Rights Reserved.   
P-MU-982-10   Ver. A  Publish:2004.05.01                                                Page: 2/ 4 
added to memory. Once all the required tags have been presented, read the Master Tag to 
return to the RUN state. 
Delete Tags 
    To remove a tag from the system, that tag must be available or the Tag Simulator must be 
used. If these are not available, the system memory must be cleared and all valid tags re-added. 
To select this function: 
Read the Master Tag twice with a time between reads of less than 2 seconds.  The RED 
lamp will light.  
→  Wait for the RED lamp to start flashing. 
  The Easiprox is now in the DELETE state. In this state every tag that is presented to the 
reader will be deleted from the system memory. (Tags can now also be deleted by using the 
optional Tag Simulator.) Once the tag or a group of tags have been deleted, read the Master Tag 
to return to the RUN state. 
Clear Memory 
    To delete all the tags from the memory including the Master Tag and Strike time, place the unit 
in the CLEAR MEMORY state. 
Read the Master Tag three times with a time between reads of less than 2 seconds.  → 
The YELLOW and RED lamps will light.  →  Wait for the YELLOW and RED lamps to start 
flashing. 
    The Easiprox is now in the CLEAR MEMORY state. Now present any tag except the Master 
Tag to the reader and all memory will be cleared. Alternatively, read the Master Tag to abort this 
function. Once the memory is cleared the YELLOW and GREEN lamps will flash to indicate that 
the memory is empty.   
 
Time Adjust 
This function sets the relay operating time for a push-button input and a valid card read. 
To select this function: 
Read the Master Tag 4 times with a time between reads of less than 2 seconds.  →  All the 
lamps will go off.  
→  Wait for the YELLOW lamp to start flashing. 
    The Easiprox is now in the TIME ADJUST state and each flash of the YELLOW lamp equates 
to 1 second of relay operation time. Once the desired time is reached (max 60 seconds), read 
the Master Tag to store the time and return to the Run state.  If TOGGLE mode is required 
simply allow the YELLOW lamp to flash until it stops automatically (after 61 flashes).    The unit 
will now be in TOGGLE mode.   
INSTALLATION 
POWER 
    Connect 8-12V AC or 10-14V DC to the 12V AC/DC terminals on the controller. The polarity of the 
connection is not important. 
ELECTRIFIED DOOR LOCK 
  The unit provides a relay output rated at 24 VDC at 3A . The following contacts, that are 
isolated from the rest of the board, are provided; normally open (NO) contact, normally closed 
(NC) contact and a common (COM). Typical connections to a door strike are shown on the 
drawing.