Raise fan with downrod assembled to
the ceiling bracket and hang fan
assembly. Be sure to rotate the
downrod ball so that the notch in the
bracket engages the slot in the ball.
Install 4 x 25 watt candelabra base
bulbs.
10
12
Align hole in downrod with hole in
yoke and install cross pin. Install
downrod into yoke. Install keeper
into cross pin.
8
Tighten 2 downrod set screws and
lock nuts.
9
Set dip switches on the Remote Transmitter and Remote
Receiver to the same settings.  This must be done so the
units will communcate properly.  If you have other fans you
can set to control from one transmitter by setting both
receivers the same as the transmitter.  If you have more
than one fan with remote.  You can set the dip switches to
different positiosns to have seperate control.
Remote Transmitter Dip swtiches
Remote Receiver Dip switches
11
Make wire connections to power source using
wire nuts provided.  Make sure that no filiments
are outside of the wirenut. After making the
wire connections, the wires should be spread
apart with the grounded conductor and the
equipment-grounding conductor on one side of
the outlet box and ungrounded conductor on
the other side of the outlet box.
16
Lift canopy to ceiling aligning the key hole slots
with the screws on the bottom of the mounting
bracket.  Rotate the canopy counter clockwise
to lock in place.  Tighten the screws to secure
the canopy.  See inset for keyhole shape
17
Install remote receiver by sliding into opening in
the Mounting bracket.  Make sure that the dip
switches on the Transmitter and the Receiver
are set to the same position.  See Fig 32 for
remote operation
14
Attach blade arms to blades using
the blade arm screws and washers
provided.
18
white
black
Make wiring connections as indicated above.
White from fan to white from remote marked
N. Orange from fan to Orange from remote
marked Light/up. Blue from fan to blue from
remote marked down light. Black from fan to
Black from remote marked L. White from
house to white from remote marked AC N .
Black from house to Black from remote
marked AC L. Connect all green ground wires
to Ground wire from House.
orange
blue
Green
white
black
House
Fan
15
fuses
Fan and light kit combinations over 35 lbs,
in both flush and downrod mode the safety
cable must be installed into the house struc-
ture beams using the 3” lag screws,washers,
and lock washers. provided.  Make sure that
when the safety cable is fully extended the
lead wires are longer than the cable and no
stress is placed on the lead wires. 
13
Safety cable installation
Safety Cable
Lag Screw
safety
cable
3” lag
screw
lock
washer
washer
Slide canopy and yoke cover on
downrod. Thread lead wires and
safety cable through downrod as
shown.
7