Hearth & Home Technologies BV4236DBI User Manual

Page of 52
7
Hearth & Home Technologies  •  BV4236DBI, BV4842DBI  •  2209-900 Rev. N  •  9/12
B.  Glass Specifications
Hearth  &  Home Technologies  appliances  manufactured 
with tempered glass may be installed in hazardous loca-
tions such as bathtub enclosures as defined by the Con-
sumer Product Safety Commission (CPSC). The tempered 
glass has been tested and certified to the requirements 
of 
ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing 
Certification Council 
SGCC# 1595 and 1597. Architectur-
al Testing, Inc. Reports 
02-31919.01 and 02-31917.01).
This statement is in compliance with 
CPSC 16 CFR Sec-
tion  1201.5  “Certification  and  labeling  requirements” 
which refers to 
15 U.S. Code (USC) 2063 stating “…Such 
certificate shall accompany the product or shall otherwise 
be  furnished  to  any  distributor  or  retailer  to  whom  the 
product is delivered.”
Some local building codes require the use of tempered 
glass  with  permanent  marking  in  such  locations.  Glass 
meeting  this  requirement  is  available  from  the  factory. 
Please contact your dealer or distributor to order.
C.  BTU Specifications
This product is listed to ANSI standards for “Vented Gas 
Fireplaces”  and  “Gas  Fired Appliances  for  Use  at  High 
Altitudes”.
May be installed in a sleeping room when the provisions 
for combustion, ventilation and dilution air are met per the 
requirements of
ANSI 223.1/NFPA 54 National Fuel Gas
Code.  In Canada, installation in a sleeping room requires 
installation with a thermostat certified for use with this prod-
uct.  Consult your local authorities having jurisdiction.
NOTICE: This installation must conform with local codes. 
In the absence of local codes you must comply with the 
National  Fuel  Gas  Code, ANSI  Z223.1-latest  edition  in 
the U.S.A. and the CAN/CGA B149 Installation Codes in 
Canada.
A.  Appliance Certification
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance.  It should not be 
factored as primary heat in residential heating calculations.
D.  High Altitude Installations
NOTICE: If the heating value of the gas has been reduced, 
these rules do not apply. Check with your local gas utility 
or authorities having jurisdiction.
When installing above 2000 feet elevation:
•  In the USA: Reduce input rate 4% for each 1000 feet 
above 2000 feet.
•  In  CANADA:  Reduce  input  rate  10%  for  elevations 
between  2000  feet  and  4500  feet. Above  4500  feet, 
consult local gas utility.
Check with your local gas utility to determine proper orifice 
size.
E.  Non-Combustible Materials Specification
Material which will not ignite and burn. Such materials are 
those consisting entirely of steel, iron, brick, tile, concrete, 
slate, glass or plasters, or any combination thereof.
Materials  that  are  reported  as  passing 
ASTM  E  136,
Standard Test Method for Behavior of Materials in a
Vertical  Tube  Furnace  at  750  ºC  and  UL763  shall  be 
considered non-combustible materials.
F.  Combustible Materials Specification
Materials made of or surfaced with wood, compressed pa-
per, plant fibers, plastics, or other material that can ignite 
and  burn,  whether  flame  proofed  or  not,  or  plastered  or 
unplastered shall be considered combustible materials.
G.  Electrical Codes
NOTICE: This appliance must be electrically wired and 
grounded in accordance with local codes or, in the absence 
of local codes, with 
National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code CSA
C22.1.
•  A 110-120 VAC circuit for this product must be pro-
tected with ground-fault circuit-interrupter protection, 
in  compliance  with  the  applicable  electrical  codes, 
when it is installed in locations such as in bathrooms 
or near sinks.
Listing and Code Approvals
MODELS:  BV4236DBI, BV4842DBI
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
B-Vent Gas Appliance
STANDARD:
ANSI Z21.50b-2009 • CSA 2.22b-2009
Models
U.S. (0-2000 ft.) or Canada (2000-4500 ft.)
Maximum
Input BTU/h
Minimum
Input BTU/h
Orifice
Size
(DMS)
BV4236DBI
US
30,000
17,000
37
CAN
27,100
15,300
38
BV4236DBI (LP)
US
30,000
16,000
52
CAN
27,000
14,400
53
BV4842DBI
US
35,000
19,500
35
CAN
31,500
17,550
36
BV4842DBI (LP)
US
32,500
18,000
51
CAN
29,250
16,200
52