Alliance Laundry Systems SFGF09*J User Manual

Page of 46
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
510977
22
3. Remove ground screw and save for use in Step 5. 
Remove wire and use in Step 6.
Figure 19 
4. Use a strain relief and insert end of power cord 
through power supply hole.
Figure 20 
5. Attach power cord ground (green) wire to rear 
bulkhead using ground screw removed in Step 3.
Figure 21 
6. Use the three screws from the accessories bag to 
attach the remaining power cord wires to the 
terminal block as follows:
a. Red wire to “L1” terminal.
b. Black wire to “L2” terminal.
c. White wire to Neutral terminal.
NOTE: When installing the white wire, loop the 
free eyelet end of the ground wire (removed in 
Step 3) and attach along with the white wire to the 
neutral (center) terminal on the terminal block.
7. Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws 
firmly may result in wire failure at the terminal 
block.
8. Secure the strain relief to the power cord, or 
wires, where they enter the dryer cabinet.
9. Check the continuity of the ground connection 
before plugging the cord into an outlet. Use an 
acceptable indicating device connected to the 
center grounding pin of the plug and the green 
screw on the back of the cabinet.
10. Reinstall access cover and screw.
D697I
1
Ground Screw
D696I
D697I
1
DRY1920N
1
White
2
“L2” Terminal
3
Black
4
Green
5
Red
6
Neutral Terminal
7
“L1” Terminal
DRY1920N
5
7
1
2
4
6
3