Installation
15
512686
NOTE: When connecting to a gas line, an 
equipment shut-off valve must be installed within 
1.8 m (6 feet) of the dryer. An 1/8 in. NPT pipe plug 
must be installed as shown for checking inlet 
pressure. Refer to Figure 8.
4. Tighten all connections securely. Turn on gas and 
check all pipe connections (internal & external) 
for gas leaks with a non-corrosive leak detection 
fluid. 
NOTE: The dryer and its appliance main gas valve 
must be disconnected from the gas supply piping 
system during any pressure testing of that system 
at test pressures in excess of 3.45 kPa (1/2 lb./in.
2
). 
Refer to Step 8 (Check Heat Source).
L.P. (Liquefied Petroleum) Gas, 93.1 MJ/m
3
 
(2500 Btu/ft
3
), service must be supplied at 10 ± 1.5 
inch water column pressure.
For proper operation at altitudes above 1070 m 
(3500 feet) the L.P. gas valve spud orifice size must be 
reduced to ensure complete combustion. Refer to 
NOTE: DO NOT connect the dryer to L.P. Gas 
Service without converting the gas valve. Install 
L.P. Gas Conversion Kit 458P3 (available at extra 
cost).
Step 4: Reverse Door, if Desired
NOTE: Doors with windows cannot be reversed.
The door on this dryer is completely reversible. To 
reverse door proceed as follows: 
1. Remove four hinge attaching screws.
2. Remove all nine screws.
D233I
1
New Stainless Steel Flexible Connector -
(Use design CSA certified connector)
Use only if allowed by local codes 
2
1/8 in. NPT Pipe Plug
3
Equipment Shut Off Valve
4
Black Iron Pipe 
Shorter than 6.1 m (20 ft.) - 9.5 mm
(Use 3/8 in.) pipe
Longer than 6.1 m (20 ft.) - use 12.7 mm (1/2 
in.) pipe. 
5
3/8 in. NPT Gas Connection
Figure 8 
D233I
1
3
2
4
5
L.P. Altitude Adjustments
Altitude
Orifice Size
Part 
No.
m
feet
No.
mm
inches
1070
3500
54
1.40
0.0550
503785
2290
7500
55
1.32
0.0520
58755
3355
11000
56
1.18
0.0465
503786
Table 3 
Figure 9 
Figure 10 
D675I
D675I
D272P