Error Display Mode
The control enters Error Display Mode to display 
thermistor errors. The heater is turned off, the IN USE 
LED flashes to indicate the error (refer to paragraphs 
below), and the timer will continue to count down 
time. The control remains in Error Display Mode until 
the control senses the thermistor has returned to an 
acceptable heating range, the cycle ends or machine is 
powered down.
Open Thermistor
If the control senses a temperature less than 0
°
F when 
the heat has been on for at least three minutes it will 
set an open thermistor error. The control will flash the 
IN USE LED twice separated by a one and a half 
second pause. This sequence is repeated as long as the 
Open Thermistor error is sensed.
Shorted Thermistor
If the control senses a temperature greater than 210 ± 
4
°
F during an active cycle it will set a Shorted 
Thermistor error. The control will flash the IN USE 
LED three times separated by a one and a half second 
pause. This sequence is repeated as long as the Shorted 
Thermistor error is sensed.
Setting Dry Time Dipswitches
To change the dry time on the dryer, combinations of 
dipswitches can be set on the control. Refer to 
Figure 25.
There are eight dipswitches on the dryer control. The 
first six switches are used to program the amount of 
additional heat time given for each coin pulse. The 
additional drying time is added to the factory default 
minimum heat time of one minute. A value of 1 to 63 
minutes of additional drying time is available for each 
coin slide pulse.
Models Through Serial No. 0908
The last two switches are used to program the amount 
of additional cool down time. The additional cool 
down time is added to the factory default minimum 
cool down time of 3 minutes. A value of 1 to 3 
additional minutes is available.
Models Starting Serial No. 0909
The seventh switch is used to program the amount of 
additional cool down time. The additional cool down 
time is added to the factory default minimum cool 
down time of 3 minutes. A value of 3 additional 
minutes is available.
The eighth switch is used for the cycle reset. If the 
switch is OFF (default), the control will save the time 
left on a cycle in case of a power failure. If the switch 
is ON, the control will clear the cycle and return to 
Ready Mode if there is a power failure.
All Models
The control is shipped from the factory programmed 
with 1 minute of minimum heat time, preset with 41 
additional minutes of drying time (dipswitches 1, 4 
and 6 in ON position) and 3 minutes of minimum cool 
down time for a total time of 45 minutes for a coin 
pulse. Refer to Table 6 for dipswitch settings.
The control reads the dipswitch settings at power-up. 
The control must be powered down to change the 
dipswitch settings.
To change the heat or cool down time for a coin pulse, 
the desired dry time dipswitches must be set to ON 
position. All other dipswitches must be in OFF 
position.
NOTE: The control must be powered down for 10 
seconds before the dipswitch can be changed. 
Models Starting Serial No. 0909
Resetting Cycle Time to Zero
To remove any cycle time that may have accumulated 
on the control during setup, the cycle time on the 
control can be reset to zero. 
To reset the time, unplug the dryer and set dipswitch 8 
to ON position. Restore power to the dryer for 10 
seconds and once again unplug dryer. Set dipswitch 8 
to OFF position and restore power to the dryer.