Buzzaround XL Owner’s Manual                                                                                                     RevA_092210 
                      X. CARE AND MAINTENANCE 
 
 
NOTE: If the main circuit breaker continues to trip, there is probably an underlying 
electrical fault that needs attention. 
 
• Contact your authorized Golden Technologies, Inc. dealer. 
• Do not keep resetting the main circuit breaker without correcting the underlying electrical 
  problem. 
 
DIAGNOSTICS 
The diagnostics feature of your Golden Buzzaround XL microprocessor based motor control 
board functions as follows: 
 
• Any fault condition with the controller or with an associated system will cause the scooter 
  to beep. 
• The number of beeps in each series is referred to as the “Beep Code.” 
• The beep code indicates the nature of the condition or fault. 
 
Beep Codes 
 
1 Beep 
• Indicates that the battery voltage (with the throttle control lever in the neutral position) is  
  below the required operating voltage of the scooter. 
• The batteries need to be charged. 
• Your Buzzaround XL will continue to operate at reduced speeds. 
• As the voltage drops you will experience a power loss. 
Remedy: Charge your Buzzaround XL’s batteries. See “Batteries and Charging” in this 
               section. 
 
2 Beeps 
• Indicates that the battery voltage is too low for the scooter to operate. 
• At this voltage your scooter will cease operation. 
• If you have charged the batteries and the condition continues, one or both of the scooter’s 
  batteries may be at fault. 
• The continuance of this condition after you have charged your Buzzaround XL’s batteries 
  may also indicate a problem with the battery charger. 
 
3 Beeps 
Consult your authorized Golden Technologies, Inc. dealer. 
 
 
 
 
 
 
 