Sterling 882.000254.00 User Manual

Page of 91
7/50D Plus or 7/50D Controller 
Chapter 4: Operation 
58 
The following table explains the status represented by each color at the Pump Summary 
screen. 
Color Label 
Description 
Gray outline 
Offline 
Pump is not enabled. The controller ignores any alarms. 
Yellow 
Ready 
Pump is off, waiting for demand from a station. 
Blue 
Idle 
Pump is on, waiting for demand from a station. If there is no 
demand before the end of the auto shutdown delay, the pump 
will turn off. 
Green 
Loading 
Pump is conveying material to a station. 
Blue, blinking 
Blow Back 
Pump’s air filter is being cleaned by blowing compressed air 
backward through it. 
Red, blinking 
Alarm 
Pump is in alarm. 
Red outline, blinking 
Critical 
Pump is in critical alarm. The controller has disabled the pump 
until the alarm is cleared. 
 
Additional information about each pump, including configuration settings and the number of 
hours the pump has been running, is available at the Pump n Setup screen. For details on 
configuration settings, see p. 78. For details on the hour meter, see p. 65.