Operating Range Requirements
9
Operating Range Requirements
The total distance between the CALLMASTER V telephone (with Recorder 
Interface active) and the recording device should not exceed 
200 feet/ 60.96 meters.
The distance between the CALLMASTER V telephone and the PBX must NOT 
exceed the following:
With 22-gauge wire, the distance between the CALMASTER V and the PBX 
should not exceed 5,500 feet/ 1,676.4 meters; with 24-gauge wire, the 
distance should not exceed 3,500 feet/ 1,066.8 meters; with 26-gauge wire, 
the distance should not exceed 2,200 feet/ 670.56 meters.
The record output impedance is approximately 600 ohms and the output 
channel is isolated from the telephone via a voice transformer that meets the 
UL 1950 Dielectric Breakdown requirement of 1,000 URMS for one minute.
Telephone Installation
The CALLMASTER V telephone can be either desk-mounted or wall-mounted. 
Read the following safety instructions and use the following directions and 
refer to the following figure of the rear of the telephone for installing these 
telephones.
FIGURE 4
The CALLMASTER V Telephone Console, Rear View
1
3
4
5
2
6
7