Polycom DOC2702A User Manual

Page of 1010
Chapter 10-Operator Assistance & Participant Move
Polycom, Inc.
10-9
6
Click the Video Quality tab.
Auto Terminate
When selected (default), the conference automatically ends when the 
termination conditions are met:
Before First Joins — No participant has connected to a conference 
during the n minutes after it started. Default idle time is 10 minutes.
At the End - After Last Quits — All the participants have 
disconnected from the conference and the conference is idle (empty) 
for the predefined time period. Default idle time is 1 minute.
At the End - When Last Participant Remains — Only one 
participant is still connected to the conference for the predefined time 
period (excluding the recording link which is not considered a 
participant when this option is selected). This option should be 
selected when defining a Profile that will be used for Gateway Calls 
and you want to ensure that the call is automatically terminated when 
only one participant is connected. Default idle time is 1 minute.
Note: The selection of this option is automatically cleared and 
disabled when the Operator Conference option is selected. The 
Operator conference cannot automatically end unless it is terminated 
by the RMX User.
Echo Suppression
When enabled (default), an algorithm is used to search for and detect 
echo outside the normal range of human speech (such as echo) and 
automatically mute them when detected.
Clear this option to disable the Echo Suppression algorithm.
Note: This option is activated only in MPM+ and MPMx Card 
Configuration Mode
.
Keyboard Noise 
Suppression
When enabled, an algorithm is used to search for and detect 
keyboard noises and automatically mute them when detected.
Note: This option is activated only in MPM+ and MPMx Card 
Configuration Mode
.
Table 10-2  
New Profile - Advanced Parameters (Continued)
Field/Option
Description