EFJohnson 001-9800-001 User Manual

Page of 127
CIRCUIT DESCRIPTION
3-26
February 2001
Part No. 001-9800-001
This effectively AC grounds the receiver end of 
the quarter-wave line through CR802 and C847. When 
one end of a quarter-wave line is grounded, the other 
end presents a high impedance to the quarter-wave 
frequency. Therefore, the VCO signal is blocked from 
the receiver by the quarter-wave line and has a low 
impedance path through CR801 to the transmitter.
In the receive mode, both diodes are reverse 
biased. The quarter-wave line is then no longer 
grounded and provides a low impedance path to the 
receiver while CR802 provides a high impedance into 
the transmitter. L801/C846 and L800/C845 improve 
isolation by neutralizing the slight capacitance of 
CR801 and CR802 when they are reverse biased.
3.10.6 SYNTHESIZER INTEGRATED CIRCUIT 
(U804)
Introduction
A block diagram of synthesizer IC U804 is shown 
in Figure 3-5 on page 5-16. This integrated circuit 
contains the following stages. The basic operation of 
U804 was described in Section 3.10.1.
Reference (R) divider
Main divider
Prescaler (÷64/65)
Phase and lock detectors
Charge pump and divider programming circuitry 
Channel Programming
Channels are selected by programming the main 
divider in U804 to divide by a certain number. This 
programming is performed by the microcontroller over 
the SPI serial data bus which consists of CLOCK, 
DATA, and STROBE lines (see Section 3.3.1). As 
previously described, this divider is programmed so 
that when the VCO is oscillating on the correct 
frequency, the fR and fV inputs to the phase detector 
are the same frequency.
Operation
As stated in Section 3.10.1, the fR input to the 
main phase detector is 50 kHz for all channels. The 
reference oscillator frequency is divided by 350 (800 
MHz) or 297 (900 MHz) to produce this signal. Frac-
tional-N division with modulo 5 or 8 selection allows 
the loop frequency to be 5 or 8 times the channel 
spacing. With 800 and 900 MHz channels, modulo 8 is 
used to allow 6.25 kHz (12.5 kHz) channel spacing.
The fV input is produced by dividing down the 
VCO frequency applied to the RF IN input. The first 
divider which divides this signal is a prescaler which 
is a special counter capable of operating at relatively 
high frequencies. The prescaler divides by 64 and 65 
which reduces a signal in the 800 MHz range down to 
approximately 12 MHz. For each main divider output 
pulse (fV), the prescaler divides by 65 for a certain 
number of pulses and then 64 for an additional number 
of pulses. The number counted in each mode is deter-
mined by the programming of the “N” and “A” 
numbers. The basic operation is as follows:
The main divider begins counting down from the 
“A” number. Then when zero is reached, it begins 
counting down from the “N” number until zero is 
reached. The cycle then repeats. While it is counting 
down the “A” number, the prescaler divides by 65, and 
while it is counting down the “N” number, it divides 
by 64.
To illustrate the operation of these dividers, an 
example will be used. Assume a transmit frequency of 
813.4875 MHz is selected (800 MHz FCC channel 
300). Since the VCO oscillates on the transmit 
frequency in the transmit mode, this is the frequency 
that must be produced by the VCO. To produce this 
frequency, the “N” and “A” divide numbers are 
programmed as follows:
N = 239
A = 13
To determine the overall divide number of the 
prescaler and main divider, the number of prescaler 
input pulses required to produce one main divider 
output pulse can be determined. Although the “N” 
number is 239 in this example, the actual divide 
number is always two higher (241) because of reset 
cycles and other effects. Therefore, the prescaler 
divides by 65 for 13 x 65 or 845 input pulses. It then 
divides by 64 for 241 x 64 or 15,424 input pulses. 
Since the VCO frequency is not evenly divisible 
by 50 kHz, there is also a fractional-N number 
programmed that provides the required fractional 
800/900 MHz SYNTHESIZER DESCRIPTION