Installation GuideTable of ContentsImportant Safety Instructions11Mechanical Loading13Reduced Airflow13Elevated Operating Ambient Temperature13Safety Plugs (USA Only)14Grounding Terminal15Safety Plugs (European Union)15FCC Statement for Class A Equipment19Industry Canada - Industrie Canadiene Statement19CENELEC/CISPR Statement with Respect to Class A Information Technology Equipment19Laser Safety21Laser Power and Warning Labels23Module Introduction25High Density Transmitter Description27High Density Transmitter Features27High Density Transmitter Operation27High Density Transmitter Optical Output28Laser Warning28High Density Transmitter Block Diagram28High Density Transmitter Front and Back Panel29High Density Transmitter Illustration29High Density Transmitter Front Panel Features29Back Panel Connectors30Host Module31Host Module Features31Host Module Illustration31Host Module Back Panel Connectors32Module Configuration33Configuration and Monitoring Methods33Configuration Summary34Overview25Purpose25Who Should Use This Document25Qualified Personnel26Scope26Document Version26Module Installation35Preparing for Installation36Equipment and Tools Needed36Unpacking and Inspecting the Module36Site Requirements37Access Requirements37Equipment Rack37Operating Environment37Power Requirements37Space Requirements38Prisma II Chassis Installation38Prisma II XD Chassis Installation38Prisma II Chassis Style38Rear-Access Chassis - Front Panel Illustration39Front-Access Chassis - Front Panel Illustration39Prisma II XD Chassis Style40Connecting the RF Cables to the Chassis41To Connect RF Cables for Each Module41Standard Prisma II Chassis41Prisma II XD Chassis42Installing the Module in the Chassis43To Install the Transmitter Modules in the Host Module43To Install the Host Module in the Chassis44To Install the Module in a Prisma II XD Chassis45Connecting Optical Cables47Fiber Fish Tool47Fiber Fish Tool Hook47To Pull the Optical Cable to the Module47Optical Connector Cleaning Overview48Recommended Equipment48Tips for Optimal Fiber-Optic Connector Performance48To Clean Optical Connectors49To Connect Optical Cables to Module50Connecting the ICIM to Additional Chassis51Chassis-to-Chassis ICIM Connections51ICIM IN and ICIM OUT Connectors51ICIM IN and ICIM OUT Cables51To Connect Chassis-to-Chassis ICIM IN and ICIM OUT Ports52Connecting a Chassis to the TNCS Server53Cable Kits for Connecting a Chassis to the TNCS Server53To Connect TNCS to the Chassis EM IN Port53Using TNCS with Multiple Chassis54External Alarms Connections55Master/Slave Operation55ALARMS IN and ALARMS OUT Connectors55ALARMS IN and ALARMS OUT Connector Illustration56Standard Prisma II Chassis56Prisma II XD Chassis56Master/Slave Illustration56Redundancy Interface Panel57Prisma II Redundancy Interface Panel Illustrations57Front Panel57Back Panel57Close-up of Front Panel Terminal Strips57Introduction35Operation using ICIM59ICIM Introduction60Laser Warning60ICIM Function60ICIM Block Diagram61ICIM2 Front Panel62ICIM2 Illustration (Front Panel)62ICIM2 Front Panel Features63ICIM LCD63ICIM MAIN Menu Illustration63ICIM Keypad64ICIM Password65Password Protection System65To Access the Password Menu65Expired Password or Inactive Password Messages66To Enter the User Password66To Change the User Password67To Disable the User Password using ICIM68Operating the ICIM70Using the ICIM70To Access the ICIM LCD Contrast70ICIM MAIN Menu70ICIM MAIN Menu Illustration71Prisma II ICIM Menu71Prisma II MAIN Menu and ICIM Menu Structure72Prisma II Transmitter Module Software Menu Structure73Checking the Operating Status using the ICIM74To Check the Operating Status using ICIM74STATUS Menus75Configuring the Module using the ICIM76To Configure Parameters using the ICIM76CONFIG Menus76Checking Module Alarms using the ICIM78To Check Alarms using ICIM78ALARMS Menus79To Set Adjustable Alarm Thresholds using the ICIM79Alarm Threshold Menus80Checking Manufacturing Data using the ICIM81To Check Manufacturing Data81MFG. DATA Menus82Saving the Configuration using the ICIM83To Save the Current Configuration83Configuration Complete83Introduction59Scope of This Chapter59Operation using LCI85LCI Introduction86Laser Warning86LCI Function86System Requirements87Computer Requirements87Cable Requirements87Installing LCI88To Install the LCI Software88Connecting Your Computer to the Chassis91To Connect a Computer to the Chassis91Starting LCI Software93To Start LCI Software93LCI Module Tree95Introduction95Module Tree95Accessing the Module Detail Information96To Access the Module Details, Right-Click the Module96Checking the Operating Status98To Check the Operating Status using LCI98Configuring the Module using LCI99To Configure Parameters using LCI99Checking the Module Alarms using LCI101To Check Alarms using LCI101Modifying Module Alarm Limits using LCI103To Modify Alarm Limits using LCI103Checking Manufacturing Data using LCI105To Check Manufacturing Data using LCI105Introduction85Maintenance and Troubleshooting107Maintenance108Maintenance Record108General Troubleshooting Information109Equipment Needed109Additional Assistance109Troubleshooting109Troubleshooting Alarm Conditions110Module Alarm Conditions110Introduction107Qualified Personnel107Customer Information111If You Have Questions111Appendix A Module Parameter Descriptions113High Density Transmitter Parameters114Operating Status Parameters114Configurable Parameters115Alarm Data Parameters116Manufacturing Data Parameters117Introduction113Glossary119ac, AC119AGC119CAN119dc, DC119DFB laser119DRR119EDFA119EIA119EMC119EMT120ESD120HD120I/O120ICIM120IP120LCD120LCI120LED120MIB120nm121NMS121OMI121PLL121QAM121RF121RMA121RT121RX121SBS121SMC122SNMP122TEC122TNCS122torque122TX122Index123Size: 3 MBPages: 126Language: EnglishOpen manual
Installation GuideTable of Contents05_Dual_Tx_Safety7Safety Precautions7Compliance9Laser Safety1006_Dual_Tx_ch112Chapter 1 Introduction12Overview12Introduction12Qualified Personnel12In This Chapter12Prisma II bdr 2:1 Dual Transmit Processor Overview13Introduction XE "transmit processor:overview"13Processor Features13Processor Operation14Optical Output14Processor Block Diagram XE "transmit processor:block diagram " XE "block diagram:transmit processor"15Processor Front Panel16Introduction16Processor Front Panel Illustration16Processor Front Panel Features16Optical Transmitter17Processor Back Panel18Introduction18Back Panel Connectors18Power and Communications Connector18Optical Transmitter Front Panel19Introduction XE "receiver front panel"19Optical Transmitter Front Panel Illustration19Optical Transmitter Front Panel Features19Optical Transmitter Identification20Introduction20Optical Transmitter Product ID Number20Processor Configuration22Introduction XE "transmit processor:configuration summary"22Configuration and Monitoring Methods22Parameter Configuration22Configure the Module in Master, Slave, or Independent Mode23Enable or Disable Noise Suppression23Enable or Disable Transmitter Sub-Module23Set the Amount of RF Attenuation23Processor Configuration Examples24Introduction24Example 1: Single Processor Configured with Two Independent Optical Transmitters24Example 2: Single Processor Configured for Internal Redundancy24Example 3: Two Processors Configured for External Redundancy (Same Chassis)25Example 4: Two Processors Configured for External Redundancy (Different Chassis)2507_Dual_Tx_ch226Chapter 2 Installation26Overview26Introduction26Qualified Personnel26In This Chapter26Prepare for Installation27Introduction27Unpacking and Inspecting the Module27Required Equipment and Tools27Site Requirements28Introduction28Access Requirements28Equipment Rack28Operating Environment28Power Requirements29Space Requirements29Chassis Style29Rear Access Chassis30Front Access Chassis30Connect RF Cables to the Chassis31Introduction31Connecting the RF Cables31Install the Processor in the Chassis33Introduction33Installing the Processor33Connect Optical Cables35Introduction35Fiber Fish Tool Overview XE "fiber fish tool"35Connecting an Optical Cable to the Processor36Connecting an Optical Cable to an Optical Transmitter37Install Optical Transmitters in the Processor38Introduction XE "installations:transmitter"38Installing the Optical Transmitter38Connect Multiple Chassis40Introduction40Cabling Requirements40Connecting the Chassis40Additional Information40Alarm I/O Connections41Introduction41ALARMS IN Connector41ALARMS OUT Connector43Prisma II Redundancy Interface Panel Overview45Introduction XE "redundancy interface panel:introduction"45Slave Mode Operation in Prisma II Modules45Redundancy Interface Panel Illustration (Front)45Redundancy Interface Panel Illustration (Rear)45Interface Panel Features46Introduction XE "redundancy interface panel:features"46Chassis Slot Numbers46Terminals Strips46Spring Terminals46Alarm Terminal Designations46Interface Panel Installation and Connections47Introduction47Cabling Requirements47Installing the Interface Panel48Connecting the Interface Panel to the Chassis48Connecting a Slave Module to a Master Module49Checking the Master/Slave Connection49Master/Slave Connections Overview50Introduction XE "redundancy interface panel:master/slave connections"50Interface Panel Terminal Strips50Typical Master/Slave Jumper Connections for Modules in the Same Chassis51Typical Master/Slave Jumper Connections for Modules in Separate Chassis5208_Dual_Tx_ch3_ICIM53Chapter 3 Operation Using the ICIM53Overview53Introduction53In This Chapter53ICIM Introduction54Introduction54ICIM Block Diagram XE "ICIM:block diagram" XE "block diagram:ICIM"54ICIM Front Panel55Introduction55ICIM Front Panel Illustration55ICIM Front Panel Features56The ICIM LCD56The ICIM Keypad57ICIM Password58Introduction58Password Protection System XE "password:ICIM"58Accessing the Password Function59Expired Password or Inactive Password Messages59Using Your Password for the First Time60Re-Entering a User Password61Changing the User Password63Disabling the User Password65ICIM Operation66Introduction66Accessing the ICIM LCD Contrast66The MAIN Menu66Prisma II ICIM Menu67Prisma II MAIN Menu Structure68Processor Software Menu Structure69Monitor Processor Status Using the ICIM70Introduction70STATUS Parameters70Checking Operating Status72STATUS Menus72Configure the Processor Using the ICIM74Introduction74CONFIG Parameters74Configuring Parameters XE "parameters:configuring with ICIM"76CONFIG Menus XE "menu:CONFIG using ICIM"77Check Processor Alarms Using the ICIM79Introduction79ALARMS Display79Alarm Thresholds81Checking Alarms XE "alarms:checking using ICIM"82Processor ALARMS Menus XE "menu:ALARM using ICIM"83Check Manufacturing Data Using the ICIM85Introduction85Checking Manufacturing Data85Manufacturing Data Display86MFG. DATA Screens87Save the Configuration Using the ICIM88Introduction88Saving the Current Configuration XE "configuration:saving using ICIM"88Configuration Complete8809_Dual_Tx_ch4_LCI89Chapter 4 Operation Using LCI89Overview89Introduction89In This Chapter89LCI Introduction90The LCI Software Function90System Requirements91Introduction91Computer Requirements91Cabling Requirements91Install LCI92Introduction92Installing the LCI Software92Obtain and Install the Prisma II Driver Upgrade95Introduction95Required Software95Obtaining the Driver Upgrade95Downloading and Installing the Driver Upgrade (LCI Software Version 1.4.3 ONLY)95Connect the Computer to the Chassis96Introduction96Connecting to the Chassis96Start LCI97Introduction97Starting the LCI Software97LCI Device Tree Overview99Introduction99Device Tree99Access the Device Details Window100Introduction100Right-Click the Chassis101Check the Operating Status103Introduction103Monitored Parameters103Checking the Operating Status104Configure the Processor105Introduction105Configurable Parameters105Configuring Parameters XE "configuration: using LCI"106Check Processor Alarms107Introduction107Alarms Limits108Checking Alarms109Check Device Properties110Introduction110Device Properties110Checking Device Properties11110_Dual_Tx_ch5MT112Chapter 5 Maintenance and Troubleshooting112Overview112Introduction112Qualified Personnel112In This Chapter112Module Maintenance113Introduction113Required Maintenance113General Troubleshooting Information114Introduction114Required Equipment114Additional Assistance114Troubleshooting114Troubleshoot Alarm Conditions115Introduction115ICIM Alarm Conditions115Troubleshoot LCI117Introduction117If the Chassis Does Not Display in the Module Tree117Specifying the Correct Communications Port118Specifying the Correct Chassis ID121Only Some of the Modules Display in the Module Tree122Clean Fiber-Optic Connectors124Introduction124Required Equipment124Tips for Optimal Fiber-Optic Connector Performance124Cleaning Optical Connectors12511-Chap6-CustInfo126Chapter 6 Customer Information126If You Have Questions126Access your company's extranet site to view or order additional technical publications. For accessing instructions, contact the representative who handles your account. Check your extranet site often as the information is updated frequently.12612_Dual_Tx_Gloss127Glossary12713_Dual_Tx_index13714-Back Cover13901-cover102-PlsRd2For Your Safety2Explanation of Warning and Caution Icons2Important203-Notices3Notices3Trademark Acknowledgments3Publication Disclaimer3Copyright3Size: 2.47 MBPages: 139Language: EnglishOpen manual
Installation GuideTable of Contents01-cover102-PlsRd2For Your Safety2Explanation of Warning and Caution Icons2Important203-Notices3Notices3Trademark Acknowledgments3Publication Disclaimer3Copyright304_Dual_Rx_TOC405_Dual_Rx_Safety7Safety Precautions7Protect Yourself From Electric Shock and Your System From Damage!7Enclosure8Cables8Factory Service8Compliance9Laser and Electrical Safety9Electromagnetic Compatibility XE "safety:precautions"9Laser Safety10Introduction10Warning: Radiation10Warning: Fiber Chips10Modifications10Laser Warning Labels1106_Dual_Rx_ch112Chapter 1 Introduction12Overview12Introduction12Qualified Personnel12In This Chapter12Prisma II bdr 2:1 Dual Receive Processor Overview13Introduction XE "receive processor:overview"13Processor Features13Prisma II bdr Digital Reverse 2:1 Multiplexing System14Optical Output14Processor Block Diagram15Processor Front Panel16Introduction16Processor Front Panel Illustration16Processor Front Panel Features16Optical Receiver17Processor Back Panel18Introduction18Back Panel Connectors18Power and Communications Connector18Optical Receiver Front Panel19Introduction XE "receiver front panel"19Optical Receiver Front Panel Illustration19Optical Receiver Front Panel Features19Processor Configuration Summary20Introduction XE "receive processor:configuration summary"20Configuration and Monitoring Methods20Parameter Configuration Summary20Processor Configuration Options21Introduction21Optical Receivers XE "configuration:options"21RF Output (Muting)21Attenuation21Alarms22Test Point Selector and -20 dB Test Point22Redundant Mode23External Connections24Factory Default Restoration24Processor Configuration Examples25Introduction25Example 1: Single Processor Configured with Two Independent Optical Receivers25Example 2: Single Processor Configured for Internal Redundancy25Example 3: Two Processors Configured for External Redundancy (Same Chassis)26Example 4: Two Processors Configured for External Redundancy (Different Chassis)2607_Dual_Rx_ch227Chapter 2 Installation27Overview27Introduction27Qualified Personnel27In This Chapter27Prepare for Installation28Introduction28Unpacking and Inspecting the Module28Required Equipment and Tools28Site Requirements29Introduction29Access Requirements29Equipment Rack29Operating Environment29Electrical Power30Chassis Slot Availability30Power Supply Installation Slot Restrictions (Slots 1 through 4 )30Front and Rear Access Chassis Styles30Rear Access Chassis31Front Access Chassis31Connect RF Cables to the Chassis32Introduction32Connecting the RF Cables32Install the Processor in the Chassis34Introduction34Installing the Processor34Connect Optical Cables36Introduction36Fiber Fish Tool Overview36Connecting an Optical Cable to the Processor37Connecting an Optical Cable to an Optical Receiver38Install Optical Receivers in the Processor39Introduction XE "installations:receiver"39Installing the Optical Receiver39Connect Multiple Chassis41Introduction41Cabling Requirements41Connecting the Chassis41Additional Information41Alarm I/O Connections42Introduction42ALARMS IN Connector42ALARMS OUT Connector44Wiring Alarm Contacts for External Redundancy46Prisma II Redundancy Interface Panel Overview47Introduction47Slave Mode Operation in Prisma II Modules47Redundancy Interface Panel Illustration (Front)47Redundancy Interface Panel Illustration (Rear)47Interface Panel Features48Introduction48Chassis Slot Numbers48Terminals Strips48Spring Terminals48Alarm Terminal Designations48Interface Panel Installation and Connections49Introduction49Cabling Requirements49Installing the Interface Panel50Connecting the Interface Panel to the Chassis50Connecting a Slave Module to a Master Module51Checking the Master/Slave Connection51Master/Slave Connections Overview52Introduction52Interface Panel Terminal Strips52Typical Master/Slave Jumper Connections for Modules in the Same Chassis53Typical Master/Slave Jumper Connections for Modules in Separate Chassis5408_Dual_Rx_ch3_ICIM55Chapter 3 Operation Using the ICIM55Overview55Introduction55In This Chapter55ICIM Introduction56Introduction56ICIM Block Diagram XE "ICIM:block diagram" XE "block diagram:ICIM"56ICIM Front Panel57Introduction57ICIM Front Panel Illustration57ICIM Front Panel Features58The ICIM LCD58The ICIM Keypad59ICIM Password60Introduction60Password Protection System XE "password:ICIM"60Accessing the Password Function61Expired Password or Inactive Password Messages61Using Your Password for the First Time62Re-Entering a User Password63Changing the User Password65Disabling the User Password67ICIM Operation68Introduction68Accessing the ICIM LCD Contrast68The MAIN Menu68Prisma II ICIM Menu69Prisma II MAIN Menu Structure70Processor Software Menu Structure71Monitor Processor Status Using the ICIM72Introduction72STATUS Parameters72Checking Operating Status74STATUS Menus74Configure the Processor Using the ICIM76Introduction76CONFIG Parameters76Configuring Parameters XE "parameters:configuring with ICIM"77CONFIG Menus XE "menu:CONFIG using ICIM"78Check Processor Alarms Using the ICIM80Introduction80ALARMS Display80Checking Alarms XE "alarms:checking using ICIM"81Processor ALARMS Menus XE "menu:ALARM using ICIM"82Check Manufacturing Data Using the ICIM84Introduction84Checking Manufacturing Data84Manufacturing Data Display85MFG. DATA Screens86Save the Configuration Using the ICIM87Introduction87Saving the Current Configuration XE "configuration:saving using ICIM"87Configuration Complete8709_Dual_Rx_ch4_LCI88Chapter 4 Operation Using LCI88Overview88Introduction88In This Chapter88LCI Introduction89The LCI Software Function89System Requirements90Introduction90Computer Requirements90Cabling Requirements90Install LCI91Introduction91Installing the LCI Software91Obtain and Install the Prisma II Driver Upgrade94Introduction94Required Software94Obtaining the Driver Upgrade94Downloading and Installing the Driver Upgrade (LCI Software Version 1.4.3 ONLY)94Connect the Computer to the Chassis95Introduction95Connecting to the Chassis95Start LCI96Introduction96Starting the LCI Software96LCI Device Tree Overview98Introduction98Device Tree98Access the Device Details Window99Introduction99Right-Click the Chassis100Check the Operating Status102Introduction102Monitored Parameters102Checking the Operating Status103Configure the Processor104Introduction104Configurable Parameters104Configuring Parameters XE "configuration: using LCI"106Check Processor Alarms107Introduction107Alarms Limits108Checking Alarms108Check Device Properties109Introduction109Device Properties109Checking Device Properties11010_Dual_Rx_ch5MT111Chapter 5 Maintenance and Troubleshooting111Overview111Introduction111Qualified Personnel111In This Chapter111Module Maintenance112Introduction112Required Maintenance112General Troubleshooting Information113Introduction113Equipment Needed113Additional Assistance113Troubleshooting113Troubleshoot Alarm Conditions114Introduction114ICIM Alarm Conditions114Troubleshoot LCI115Introduction115If the Chassis Does Not Display in the Module Tree115Specifying the Correct Communications Port116Specifying the Correct Chassis ID119Only Some of the Modules Display in the Module Tree120Clean Fiber-Optic Connectors122Introduction122Required Equipment122Tips for Optimal Fiber-Optic Connector Performance122Cleaning Optical Connectors12311-Chap6-CustInfo124Chapter 6 Customer Information124Overview124If You Have Questions12412_Dual_Rx_Gloss125Glossary12513_Dual_Rx_index13514-Back Cover137Size: 4.32 MBPages: 137Language: EnglishOpen manual
Installation GuideTable of Contents01-cover102-PlsRd2For Your Safety2Explanation of Warning and Caution Icons2Important203-Notices3Notices3Trademark Acknowledgments3Publication Disclaimer3Copyright304-TOC-Comp4Contents4Contents, Continued5Safety Precautions6Compliance8Laser Safety9Laser Safety, Continued1005-ch1-intro11Chapter 1Introduction11Overview11Introduction11Qualified Personnel11In This Chapter11Introduction12Overview12Features12Prisma II Reverse Receiver Operation13Optical Input13Block Diagram14The Front Panel15Overview15The Back Panel16Back Panel Connectors16Power and Communications Connector16Configuration Overview17Overview17Configuration and Monitoring Methods XE "Methods:Configuration" \t ""17Configuration Summary1706-ch2-install18Overview18Introduction18Qualified Personnel18In This Chapter18Preparing for Installation19Overview19Unpacking and Inspecting the Module19Equipment and Tools Needed19Site Requirements20Overview20Access Requirements20Equipment Rack20Operating Environment20Site Requirements, Continued21Power Requirements21Space Requirements21Chassis Style21Site Requirements, Continued22Rear Access Chassis Illustration22Front Access Chassis Illustration22Connecting the RF Cables to the Chassis23RF Cable Connection Procedure23Installing the Module in the Chassis24Installing the Module24Connecting Optical Cables26The Fiber Fish Tool26The Fiber Fish Tool Hook26Connecting Optical Cables, Continued27Using the Fiber Fish to Pull the Optical Cable to the Prisma II Module27Connecting Optical Cables, Continued28Cable Connection Procedure28Communications Connections29ICIM IN/ICIM OUT and EM IN/EM OUT Cables29ICIM IN/ICIM OUT Connections29Communications Connections, Continued30ICIM IN/ICIM OUT Connection Procedure30EM OUT / IN Connections30EM OUT / EM IN Connection Procedure30Master/Slave Connections31Master/Slave Operation31Alarm In/Out Connector Reference31Master/Slave Connections, Continued3207-ch3_ICIM33Chapter 3Operation Using the ICIM33Overview33Introduction33Scope of this Chapter33In This Chapter33ICIM Introduction34ICIM Function34ICIM Block Diagram34The ICIM Front Panel35ICIM Front Panel Illustration XE "Operation:Front Panel:ICIM"35The ICIM Front Panel, Continued36ICIM Front Panel Features36The ICIM LCD36The ICIM Front Panel, Continued37The ICIM Key Pad37The ICIM Password38Using the ICIM Password38Accessing the Password Menu39Expired Password or Inactive Password Messages39The ICIM Password, Continued40Entering the User Password40The ICIM Password, Continued41Changing the User Password41The ICIM Password, Continued42Disabling the User Password42Operating the ICIM43Using the ICIM43Accessing the ICIM LCD Contrast43The MAIN Menu43Operating the ICIM, Continued44Prisma II ICIM Menu44Operating the ICIM, Continued45Prisma II MAIN Menu and ICIM Menu Structure45Prisma II Reverse Receiver Software Menu Structure45Monitoring Operating Status Using the ICIM46Monitored Parameters46Checking Operating Status46Monitoring Operating Status Using the ICIM, Continued47STATUS Menus47Configuring the Reverse Receiver Using the ICIM48Configurable Parameters48Configuring the Reverse Receiver Using the ICIM, Continued49Configuring Parameters49Configuring the Reverse Receiver Using the ICIM, Continued50CONFIG Menus50Checking Reverse Receiver Alarms Using the ICIM51Checking Alarms51Checking Reverse Receiver Alarms Using the ICIM, Continued52User Alarm Data Display52User Alarm Menus52Checking Reverse Receiver Alarms Using the ICIM, Continued53Module Alarm Data Display53Module Alarm Menus53Checking Reverse Receiver Alarms Using the ICIM, Continued54Setting User Alarm Thresholds54Reverse Receiver Alarm Threshold Menus54Checking Manufacturing Data Using the ICIM55Checking Manufacturing Data55Checking Manufacturing Data Using the ICIM, Continued56Manufacturing Data Display56MFG. DATA Menus56Checking Manufacturing Data Using the ICIM, Continued57Using the ICIM to Save the Configuration58Saving the Current Configuration58Configuration Complete5808-ch4_LCI59Chapter 4Operation Using LCI59Overview59Introduction59Scope of this Chapter59In This Chapter59LCI Introduction61LCI Function61System Requirements62Introduction62Laptop Computer Requirements62Connecting the PC to the Prisma II Chassis62Installing LCI63Introduction63Installing the LCI Software63Connecting Your Laptop Computer to the Chassis67Introduction67Connecting to the Chassis67Starting LCI68Introduction68Starting LCI68LCI Module Tree Overview69Introduction69Module Tree69Module Information70Accessing the Module Details Window71Introduction71Double-Click the Chassis72Right-Click the Chassis74Double-Click the Module76Right-Click the Module77Checking the Operating Status78Introduction78Monitored Parameters78Checking the Operating Status79Configuring the Reverse Receiver80Introduction80Configurable Parameters80Configuring Parameters81Checking Reverse Receiver Alarms83Introduction83Checking Alarms84Modifying Reverse Receiver Alarm Limits85Introduction85Modifying Alarm Limits86Checking Manufacturing Data88Introduction88Manufacturing Data88Checking Manufacturing Data8909-ch5-maint90Chapter 5Maintenance and Troubleshooting90Overview90Introduction90Qualified Personnel90In This Chapter90Module Maintenance91Maintaining the Prisma Module91Maintenance Record91General Troubleshooting Information92Introduction92Equipment Needed92Additional Assistance92Troubleshooting92Troubleshooting Alarm Conditions93Alarm Conditions9310-Ch6-custinfo94Chapter 6 Customer Information94If You Have Questions94Access your company's extranet site to view or order additional technical publications. For accessing instructions, contact the representative who handles your account. Check your extranet site often as the information is updated frequently.9411-glos95Glossary95Blank Page105Size: 3.18 MBPages: 106Language: EnglishOpen manual
Installation GuideTable of Contents01-cover102-PlsRd2For Your Safety2Explanation of Warning and Caution Icons2Important203-Notices3Notices3Trademark Acknowledgments3Publication Disclaimer3Copyright304-TOC4Contents4Contents, Continued5Safety Precautions6Compliance705-ch1-intro8Chapter 1 Introduction8Overview8Introduction8Qualified Personnel8In This Chapter8HEDA Description9Overview9The Headend Driver Amplifier as Part of the Prisma Platform9HEDA Features9HEDA Function10Headend Driver Amplifier Theory of Operation10Forward HEDA Block Diagram11Reverse HEDA Block Diagram11The HEDA Front Panel12Front Panel Description12The HEDA Front Panel, Continued13Power and Alarm Indicators13-20 dB Test Point13The HEDA Rear Panel14HEDA Rear Panel Connectors14Power and Communications Connector1406-ch2-install15Overview15Introduction15Qualified Personnel15In This Chapter15Preparing for Installation16Overview16Unpacking and Inspecting the Module16Equipment and Tools Needed16Site Requirements17Overview17Access Requirements17Equipment Rack17Operating Environment17Site Requirements, Continued18Power Requirements18Space Requirements18Chassis Style18Site Requirements, Continued19Rear Access Chassis19Front Access Chassis illustration19Connecting the RF Cables to the Chassis20RF Cable Connection Procedure20Installing the Module in the Chassis21Installing the HEDA Module2107-ch3-op23Chapter 3Operation23Overview23Introduction23Qualified Personnel23In This Chapter23Operating the HEDA24Operation24Operating the HEDA, Continued25Verifying RF Output25Ensuring Proper Signal Strength and Adjusting the Selectable Pad26Variable Pad Adjustment Procedure26Ensuring a Flat Output Signal by Adjusting the Step Equalizer27Variable Equalizer Adjustment Procedure27Ensuring a Flat Output Signal by Adjusting the Variable Equalizer, Continued28Checking the Operating Settings29Preparing to Record Operating Data29Check the RF Input29Checking the Operating Settings, Continued30Checking RF Output30Checking Pad and Tilt Settings3008-ch4-maint31Chapter 4Maintenance and Troubleshooting31Overview31Introduction31Qualified Personnel31In This Chapter31HEDA Maintenance32Maintaining the HEDA32Maintenance Record32General Troubleshooting Information33Introduction33Equipment Needed33Additional Assistance33Troubleshooting33Troubleshooting Alarm Conditions34Headend Driver Amplifier Alarm Conditions34Power Supply Related Alarms35Power Supply Related Alarms Solutions3509-Chap536Chapter 5 Customer Information36Overview36Introduction3610-glos37Glossary3711-Back Cover47Size: 741 KBPages: 47Language: EnglishOpen manual
Installation GuideTable of ContentsImportant Safety Instructions11Mechanical Loading13Reduced Airflow13Elevated Operating Ambient Temperature14Safety Plugs (USA Only)14Grounding Terminal15Safety Plugs (European Union)15FCC Statement for Class A Equipment19Industry Canada - Industrie Canadiene Statement19CENELEC/CISPR Statement with Respect to Class A Information Technology Equipment19Laser Safety21Module Introduction27Hybrid Amplifier Description29Hybrid Amplifier Features29Hybrid Amplifier Operation29Hybrid Amplifier Optical Output29Laser Warning29Hybrid Amplifier Module Block Diagram30Hybrid Amplifier Front and Back Panel31Hybrid Amplifier Illustration (Front and Back)31Hybrid Amplifier Front Panel Features31Back Panel Connectors32Module Configuration33Configuration and Monitoring Methods33Overview27Purpose27Who Should Use This Document27Qualified Personnel28Document Version28Module Installation35Preparing for Installation36Unpacking and Inspecting the Module36Equipment and Tools Needed36Site Requirements37Access Requirements37Equipment Rack37Operating Environment37Power Requirements37Space Requirements38Chassis Style38Front-Access Chassis - Front Panel Illustration38Rear-Access Chassis - Front Panel Illustration39Installing the Module in the Chassis40To Install the Module40To Enable Optical Output41To Set Up a HyperTerminal Serial Port Session with the ICIM242To Set Up a Telnet Session with the ICIM44Cleaning Optical Connectors46Introduction46Recommended Equipment46Tips for Optimal Fiber Optic Connector Performance46To Clean Optical Connectors47Fiber Optic Connector Cleaning Instructions47Connectors and Bulkheads47Cleaning Connectors48Cleaning Bulkheads48Verifying Equipment Operation49For Further Assistance49Connecting Optical Cables50To Connect Cable50External Alarms Connections51Master-Slave Operation51ALARMS IN and ALARMS OUT Connections51Master-Slave Illustration52ALARMS IN Connector52ALARMS OUT Connector52Prisma II Redundancy Interface Panel53Introduction35Operation Using CLI55Prisma II Platform Configuration56Using the CLI57CLI Overview57CLI Command Modes57Selecting Command Modes58Entering Commands - Modal Format58Entering Commands - Non-Modal Format59Command Syntax59Usage Guidelines60End of Line60Wildcards60Command Hints and Help61Abbreviations and Shortcuts61Alarm Information62Getting Online Help62Login and Logout62Login63Logout63Module Commands64Overview64Basic Command Syntax64Entering Modspecs64Module Command Prompt65Alarm Command65Alarm Module66Show Command66Show Control66Show Monitor66Show Alarmstate67Show Alarmparam67Show Module68Info Command68Reset Command71Set Command71Set Control71Set Alarmparam72ICIM Commands74Alarm Command74Info Command74Show Command76Show Domain76Show Provisioning77Show Traps77Show Clock78Set Command78Set Clock79User Command79User Add79User Change79User Delete80User Show80IPRoute Command80IPRoute Add80IPRoute Delete80IPRoute Show81Reboot Command81Traps Command81Terminal Commands82Overview82Colsep Command82Paging Command83Disabling Paging84Enabling Paging86Pattern Command86Headers Command87Show Command88Introduction55Laser Warning55Operation Using ICIM89ICIM Introduction91Laser Warning91ICIM Function92ICIM Block Diagram92ICIM Front Panel93ICIM2 Illustration (Front Panel)93ICIM2 Front Panel Features93ICIM2 LCD94ICIM Keypad95ICIM Password96Password Protection System96To Access the Password Menu96Expired Password or Inactive Password Messages97To Enter the User Password97To Change the User Password98To Disable the User Password using ICIM99Operating the ICIM101Using the ICIM101Accessing the ICIM LCD Contrast101ICIM MAIN Menu101ICIM MAIN Menu Illustration102Prisma II ICIM Menu102Prisma II MAIN Menu and ICIM Menu Structure103Hybrid Amplifier Software Menu Structure104Checking the Operating Status using the ICIM105To Check Operating Status using the ICIM105STATUS Menus106Configuring the Module using the ICIM107To Configure Parameters using the ICIM107CONFIG Menus108Hybrid Amplifier Service Mode108To Change Service Mode on the Hybrid Amplifier109Checking Alarms using the ICIM110To Check Alarms using the ICIM110To View Active User Alarms111To Set Adjustable Alarm Thresholds using the ICIM111To Check Alarm Thresholds112Alarm Threshold Menus112To View Active Module Alarms113Module Alarm Menus113Checking Manufacturing Data using the ICIM114To Check Manufacturing Data114MFG. DATA Menus115Saving the Configuration using the ICIM116To Save the Current Configuration116Configuration Complete116SNMP Configuration117SNMP Considerations117Basic SNMP Setup117To Set Up the IP Configuration Parameters for SNMP Support using ICIM118To Restart the ICIM by Removing the ICIM119Community Strings120Default Community Strings120Setting SNMP Trap Receiver Parameters121To Set Traps for a Specific IP Address using P2TrapRecvEntry121New SNMP Variables122Table of Inserted Modules122Table of Removed Modules122Previous IP Address123Boot Dialog for ICIM/SNMP Configuration124To Prepare to Change Parameters125To Change Parameters126To Restart the ICIM using ICIM127Adjusting Alarm Thresholds128To Adjust Alarm Thresholds128Introduction89Scope of This Chapter89Operation Using LCI129LCI Introduction130Laser Warning130LCI Function130System Requirements131Computer Requirements131Cable Requirements131Installing LCI132To Install the LCI Software132Connecting Your Computer to the Chassis136To Connect the Computer to a Prisma II Chassis136Starting LCI Software137To Start LCI Software137LCI Module Tree139Introduction139Module Tree139Accessing Module Details140Module Details Window140Checking the Operating Status141To Check Operating Status using LCI141Configuring the Module using LCI143To Configure Parameters using LCI143Checking the Module Alarms using LCI145To Check Alarms using LCI145Modifying Module Alarm Limits using LCI147To Modify Alarm Limits using LCI147Checking Manufacturing Data using LCI149To Check Manufacturing Data using LCI149Introduction129Maintenance and Troubleshooting151Module Maintenance152Recommended Maintenance152Maintenance Record152General Troubleshooting Information153Introduction153Equipment Needed153Additional Assistance153Troubleshooting153Troubleshooting Alarm Conditions154Amplifier Alarm Conditions154Introduction151Qualified Personnel151Customer Support155Introduction155Appendix A Prisma II Permitted CLI Commands157From CLI158From ICIM159From */* MODULE165From TERMINAL168Introduction157Appendix B Module Parameter Descriptions169Hybrid Amplifier Parameters170Hybrid Amplifier Operating Status Parameters170Hybrid Amplifier Configurable Parameters171Hybrid Amplifier Alarm Data Parameters171Hybrid Amplifier Manufacturing Data Parameter Examples173Introduction169Glossary175ac, AC175AGC175CA175CAN175CLI175DAVIC175dc, DC175DFB laser175DOCSIS176EDFA176EIA176EMC176EMS176EMT176ESD176FTTP176HFC176I/O176ICIM177IP177LCD177LCI177LED177MIB177nm177NMS177OLT177OMI177ONT178PID178PLL178PON178QAM178RF178RMA178RT178RX178SA178SBS179SI179SMC179SNMP179TEC179TNCS179torque179TX179Index181Size: 3.88 MBPages: 184Language: EnglishOpen manual
Installation GuideTable of ContentsCisco Prisma II EDR Transmitter Installation Guide1For Your Safety3Notices4Table of Contents5Important Safety Instructions7Safe Operation for Software Controlling Optical Transmission Equipment17Warning Labels19Module Introduction21EDR 85 System Overview23Features23System Block Diagram24System Description25Transmitter Operation26Receiver Operation27Prisma II EDR Transmitter Overview29Transmitter Features29Transmitter Status Indicators29Transmitter Optical Input30Laser Warning30EDR Transmitter Front and Back Panel31Transmitter Illustration (Front and Back)31Transmitter Front Panel Features31Back Panel Connectors32About the OPM32Laser Warning33Prisma II Chassis Host Module34Host Module Features34Host Module Illustration34Host Module Back Panel Connectors35Module Configuration36Configuration Summary36System Installation37Preparing for Installation38Equipment and Tools Needed38Unpacking and Inspecting the Module38Site Requirements39Access Requirements39Equipment Rack39Operating Environment39Power Requirements39Space Requirements40Prisma II Standard Chassis Style40Prisma II XD Chassis Style42Connecting the RF Cables to the Chassis43To Connect RF Cables for Each Module43Installing the HD Module in the Chassis45To Install the Application Modules in the Host Module45To Install the Module in the Chassis46To Install the Module in a Prisma II XD Chassis47Cleaning Optical Connectors49Recommended Equipment49Tips for Optimal Fiber Optic Connector Performance49To Clean Optical Connectors50Connecting Optical Cables51Cable Routing - Prisma II Chassis51Cable Routing - Prisma XD Chassis52To Connect Optical Cables to Module52Transmitter Module Setup Procedure54Maintenance and Troubleshooting55Maintenance56Maintenance Record56General Troubleshooting Information57Troubleshooting57Equipment Needed57Transmitter Module Troubleshooting Chart58Additional Assistance58Customer Information59Glossary61Index65Back Cover68Size: 1.53 MBPages: 68Language: EnglishOpen manual
Data SheetTable of ContentsDescription1Features1Prisma II XD Chassis2Specifications2Electrical2Units2Notes2Environmental2Units2Notes2Physical Dimensions2Units2Notes2Ordering Information2Prisma II XD Chassis Power Supply Module3Specifications3AC Power Supply3Units3Notes3Environmental3Units3Notes3Physical Dimensions3Units3Notes3Ordering Information3Intelligent Communications Interface Module (ICIM)4Specifications4Electrical4Units4Notes4Environmental4Units4Notes4Physical Dimensions4Units4Notes4Ordering Information4Size: 671 KBPages: 4Language: EnglishOpen manual
Data SheetTable of ContentsNotes478 CW NTSC (55-550 MHz) with up to 75 QAM256 (-6 dB, 550-1002 MHz)4Notes4Size: 345 KBPages: 5Language: EnglishOpen manual
Installation GuideTable of ContentsReceiver Description3Receiver Overview3Receiver Features3Receiver Operation3Receiver Operating Modes5Receiver Optical Input9Laser Warning9Receiver Block Diagram9EDR Receiver Front and Back Panel10Receiver Illustration (Front and Back)10Receiver Front Panel Features10Back Panel Connectors11Host Module12Host Module Features12Host Module Illustration13Host Module Back Panel Connectors14Module Configuration15Configuration and Monitoring Methods15Configuration Summary16Preparing for Installation18Unpacking and Inspecting the Module18Equipment and Tools Needed18Site Requirements19Access Requirements19Equipment Rack19Operating Environment19Power Requirements19Space Requirements20Prisma II Standard Chassis Style20Prisma II XD Chassis Style22Connecting the RF Cables to the Chassis23To Connect RF Cables for Each Module23Installing the Module in the Chassis25To Install the Receiver Modules in the Host Module25To Install the Module in the Chassis27To Install the Module in a Prisma II XD Chassis28Cleaning Optical Connectors30Recommended Equipment30Tips for Optimal Fiber Optic Connector Performance30To Clean Optical Connectors31Connecting Optical Cables32Cable Routing - Prisma II Chassis32Cable Routing - Prisma XD Chassis33To Connect Optical Cables to Module34Connecting the ICIM to Additional Chassis36ICIM IN and ICIM OUT Connectors36ICIM IN and ICIM OUT Cables36To Connect Chassis-to-Chassis ICIM IN and ICIM OUT Ports37Configuring Redundancy38External Alarm Connections38ALARMS IN and ALARMS OUT Connectors38ALARMS IN and ALARMS OUT Connector Illustration39Master/Slave Illustration40Redundancy Interface Panel40Prisma II Redundancy Interface Panel Illustrations41ICIM Introduction45Laser Warning45ICIM Function45ICIM Block Diagram46ICIM2 Front Panel47ICIM2 Illustration (Front Panel)47ICIM2 Front Panel Features48ICIM LCD48ICIM MAIN Menu Illustration48ICIM Keypad49ICIM Password50Password Protection System50To Access the Password Menu51Expired Password or Inactive Password Messages51To Enter the User Password51To Change the User Password52To Disable the User Password using ICIM53Operating the ICIM55Using the ICIM55To Access the ICIM LCD Contrast55ICIM MAIN Menu55ICIM MAIN Menu Illustration56Prisma II ICIM Menu56Prisma II MAIN Menu and ICIM Menu Structure57EDR Receiver Software Menu Structure58Checking the Operating Status using the ICIM60To Check the Operating Status using ICIM60STATUS Menus61Configuring the Module using the ICIM62To Configure Parameters using the ICIM62Alarm Threshold Menus63CONFIG Menus64Checking Alarms using the ICIM65To Check Alarms using ICIM65ALARMS Menus66To Set Adjustable Alarm Thresholds using the ICIM66Checking Manufacturing Data using the ICIM67To Check Manufacturing Data67MFG. DATA Menus68Saving the Configuration using the ICIM69To Save the Current Configuration69Configuration Complete69SNMP Configuration70SNMP Considerations70Basic SNMP Setup70ICIM71To Restart the ICIM by Removing the ICIM72Community Strings73Default Community Strings73Setting SNMP Trap Receiver Parameters74To Set Traps for a Specific IP Address using P2TrapRecvEntry74New SNMP Variables75Table of Inserted Modules75Table of Removed Modules76Previous IP Address76Adjusting Alarm Thresholds77To Adjust Alarm Thresholds77LCI Introduction80LCI Function80System Requirements81Computer Requirements81Cable Requirements81Installing LCI82To Install the LCI Software82Connecting Your Computer to the Chassis86To Connect a Computer to the Chassis86Starting LCI Software88To Start LCI Software88LCI Module Tree90Module Tree90Accessing the Module Detail Information91Module Details Window92To Access the Module Details, Right-Click the Module93Checking the Operating Status94To Check Operating Status using LCI94Configuring the Module using LCI95To Configure Parameters using LCI95Checking the Module Alarms using LCI97To Check Alarms using LCI97Modifying Module Alarm Limits using LCI98To Modify Alarm Limits using LCI98Checking Manufacturing Data using LCI100To Check Manufacturing Data using LCI100Maintenance102Maintenance Record102General Troubleshooting Information103Equipment Needed103Additional Assistance103Troubleshooting103Troubleshooting Alarm Conditions104Module Alarm Conditions104Receiver Parameters for GS7000 Nodes111Operating Status Parameters111Control Parameters112Alarm Parameters114Manufacturing Data Parameters116Receiver Parameters for Compact Nodes117Operating Status Parameters117Control Parameters118Alarm Parameters121Manufacturing Data Parameters122Receiver Parameters for GainMaker Nodes123Operating Status Parameters123Control Parameters124Alarm Parameters126Manufacturing Data Parameters127Receiver Description3EDR Receiver Front and Back Panel10Host Module12Module Configuration15Preparing for Installation18Site Requirements19Connecting the RF Cables to the Chassis23Installing the Module in the Chassis25Cleaning Optical Connectors30Connecting Optical Cables32Connecting the ICIM to Additional Chassis36Configuring Redundancy38ICIM Introduction45ICIM2 Front Panel47ICIM Password50Operating the ICIM55Checking the Operating Status using the ICIM60Configuring the Module using the ICIM62Checking Alarms using the ICIM65Checking Manufacturing Data using the ICIM67Saving the Configuration using the ICIM69SNMP Configuration70Community Strings73Setting SNMP Trap Receiver Parameters74New SNMP Variables75Adjusting Alarm Thresholds77LCI Introduction80System Requirements81Installing LCI82Connecting Your Computer to the Chassis86Starting LCI Software88LCI Module Tree90Accessing the Module Detail Information91Checking the Operating Status94Configuring the Module using LCI95Checking the Module Alarms using LCI97Modifying Module Alarm Limits using LCI98Checking Manufacturing Data using LCI100Maintenance102General Troubleshooting Information103Troubleshooting Alarm Conditions104Receiver Parameters for GS7000 Nodes111Receiver Parameters for Compact Nodes117Receiver Parameters for GainMaker Nodes123Size: 5.11 MBPages: 162Language: EnglishOpen manual
Data SheetTable of ContentsFeatures1Specifications2Forward Receiver RF Output Level Vs Optical Modulation Index2Specifications, continued3Ordering Information4Size: 915 KBPages: 4Language: EnglishOpen manual
Data SheetTable of ContentsFeatures1Transmitter Modules1Size: 182 KBPages: 8Language: EnglishOpen manual
Data SheetTable of ContentsDescription1The Prisma II High Density Platform consists of the following modules:1Premium 1310 nm High Density Transmitters1Standard 1310 nm High Density Transmitters1High Density Host Module1Common Features2Specifications3Optical3Units3HDTx Premium3HDTx Standard3Notes3Electrical3Environmental3Mechanical (Modules)3Link Performance Specifications4Premium HDTx4Carrier to Noise4(see notes: 1,3,4,5)478 CW NTSC with 53 QAM256 (550-870 MHz)464 CW PAL B/G or 59 CW PAL D/K with 33 QAM256 (600-870 MHz)4Model #4Output4Power4(dBm)4Total Optical Link Loss (dB)34Standard HDTx4Carrier to Noise4(see notes: 1,3,4,5)478 CW NTSC with 53 QAM256 (550-870 MHz)464 CW PAL B/G or 59 CW PAL D/K with 33 QAM256 (600-870 MHz)4Model #4Output4Power4(dBm)4Total Optical Link Loss (dB)34Distortion Performance4(all HD-Tx’s)478 CW NTSC with up to 75 QAM256 (550-1002 MHz)464 CW PAL B/G or 59 CW PAL D/K with up to 50 QAM256 (600-1002 MHz)4Notes4256 QAM BER Performance4(all HD-Tx’s)478 CW NTSC (55-550 MHz) with up to 75 QAM256 (-6 dB, 550-1002 MHz)4Notes4Ordering Information5Forward Transmitter5Model Number5Part Number5SC/APC5SC/UPC5E20005Size: 377 KBPages: 5Language: EnglishOpen manual
Data SheetTable of ContentsDescription1Ancillary Modules1Features1Head End Driver Amplifiers2Description2Features2Head End Driver Amplifiers, continued3Specifications3Head End Driver Amplifiers, continued4Ordering Information4Prisma II 1310/1550 nm Optical Switches5Features5Prisma II 1310/1550 nm Optical Switches, continued6Specifications6Optical6Units6Notes6Electrical6Environmental6Mechanical6Prisma II 1310/1550 nm Optical Switches, continued7Ordering Information7Size: 3.9 MBPages: 7Language: EnglishOpen manual