User ManualTable of ContentsSYSTEM OVERVIEW1TABLE OF CONTENTS5ORDERING INFORMATION9List Options9List Options (Numbers)9List Options (Letters) (Distribution Bus Arrangements)11Accessory Options15LIST DESCRIPTIONS16List 1: Main Bay Common Equipment (Power and Distribution)16List 2: Supplemental Bay Common Equipment (Power and Distribution) (located next to Main Bay)17List 4: “Distribution Only” Option for Lists 2 or 518List 5: Supplemental Bay Common Equipment (Power and Distribution) (located away from Main Bay)18List 10: MCA (Standard Application)19List 11: MCA (Special Application)19List 12: MCA (Special Application)20List 13: MCA (Special Application)20List 21: One-Row Distribution Cabinet20List 22: Two-Row Distribution Cabinet21List 23: Three-Row Distribution Cabinet22List 24: Four-Row Distribution Cabinet22List 29: Top Shield for Distribution Cabinet23List 30: Module Mounting Assembly Interface Components23List 31: Field Expansion Kit: One (1) 8-Position Module Mounting Assembly24List 50: Rectifier Module (PCU)25List 60: DC-DC Converter Option Interface Component Kit25List 62: DC-DC Converter Module26List 71: Optional Audible Alarm and Alarm Termination Circuit Card26List 72: MCA Interface Modem Option26List 73: MCA Interface WinLink Software27List 74: MCA Interface Combination Modem/RS-232 Option27List 75: MCA Interface Ethernet Option: WinLink Compatible + Web Interface28List 76: MCA Interface Ethernet Option: WinLink Compatible + Web Interface + SNMP28List 77: MCA Interface Ethernet Option: WinLink Compatible + Web Interface + Battery Monitoring29List 78: MCA Interface Ethernet Option: WinLink Compatible + Web Interface + SNMP + Battery Monitoring29List 92: Battery Stand System30List 93: Battery Tray, Pre-Cabled30List AA: Distribution Bus Module (P/N 509840) (24) Fuse/Circuit Breaker System Positions33List AB: Distribution Bus Module (P/N 428316100) (3) GJ/218 Circuit Breaker System Positions34List AC: Distribution Bus Module (P/N 507198) (3) GJ/218 Circuit Breaker System Positions35List AD: Distribution Bus Module (P/N 509565) (8) GJ/218 Circuit Breaker System Positions (Upper Two Rows)36List AE: Distribution Bus Module (P/N 509648) (8) GJ/218 Circuit Breaker System Positions (Lower Two Rows)37List AG: Distribution Bus Module (P/N 514010) (2) TPH Fuse System Positions38List AH: Distribution Bus Module Ground Bar Assembly (P/N 500676) for Use with Up to (2) List AG, AJ, CG, or CJ39List AJ: Distribution Bus Module (P/N 520819) (2) TPH Fuse System Positions with Load Metering Shunts40List AK: Distribution Bus Module (P/N 520805) (24) Fuse/Circuit Breaker System Positions41List AL: Distribution Bus Module Ground Bar Assembly for Use with Up to (2) List AK42List AM: Distribution Bus Module (P/N 524632) (20) Fuse/Circuit Breaker System Positions (1) 3-Pole Input Disconnect Fuse/Circuit Breaker Position43List BA: Distribution Bus Module (P/N 520534) (12) Fuse/Circuit Breaker System Positions with LVD (8) Fuse/Circuit Breaker System Positions without LVD44List CA: Distribution Bus Module (P/N 509848) (20) Fuse/Circuit Breaker System Positions w/LVLD45List CB: Distribution Bus Module (P/N 513738) (3) GJ/218 Circuit Breaker System Positions w/LVLD46List CD: Distribution Bus Module (P/N 507200) (3) GJ/218 Circuit Breaker System Positions w/LVLD47List CE: Distribution Bus Module (P/N 509564) (8) GJ/218 Circuit Breaker System Positions w/LVLD (Upper Two Rows)48List CF: Distribution Bus Module (P/N 509647) (8) GJ/218 Circuit Breaker System Positions w/LVLD (Lower Two Rows)49List CG: Distribution Bus Module (P/N 514035) (2) TPH Distribution Fuse Positions w/LVLD50List CJ: Distribution Bus Module (P/N 520936) (2) TPH Distribution Fuse Positions with Load Metering Shunts and LVLD51List EA: Distribution Bus Module (P/N 509852) (16) Fuse/Circuit Breaker System Positions and (4) Fuse/Circuit Breaker Battery Disconnect Positions52List GB: Distribution Bus Module (P/N 513806) (8) Fuse/Circuit Breaker System Positions w/LVD and (1) TPH Fuse Battery Disconnect Position53List JA: Distribution Bus Module (Part No. 509906) (4) +24V Fuse/Circuit Breaker System Positions and (16) –48V Fuse/Circuit Breaker Subsystem Positions54List JB: Distribution Bus Module (Part No. 513808) (12) +24V Fuse/Circuit Breaker System Positions and (8) –48V Fuse/Circuit Breaker Subsystem Positions55List JC: Distribution Bus Module (Part No. 524403) (14) +24V Fuse/Circuit Breaker System Positions and (6) –48V Fuse/Circuit Breaker Subsystem Positions56List JD: Distribution Bus Module (Part No. 524788) (14) +24V Fuse/Circuit Breaker System Positions and (8) –48V Fuse/Circuit Breaker Subsystem Positions57List KA: Distribution Bus Module (Part No. 520507) (4) +24V Fuse/Circuit Breaker System Positions and (16) –48V Fuse/Circuit Breaker Subsystem Positions58List LB: Distribution Bus Module (Part No. 513807) (8) +24V Fuse/Circuit Breaker System Positions w/LVD and (8) –48V Fuse/Circuit Breaker Subsystem Positions59List LC: Distribution Bus Module (Part No. 514623) (12) +24V Fuse/Circuit Breaker System Positions w/LVD and (4) –48V Fuse/Circuit Breaker Subsystem Positions60List NA: Distribution Bus Module (P/N 514336) (20) Fuse/Circuit Breaker Battery Disconnect Positions61List NB: Distribution Bus Module (P/N 513809) (3) GJ/218 Circuit Breaker Battery Disconnect Positions62List NC: Distribution Bus Module (P/N 514025) (1) TPH Fuse Battery Disconnect Position63List ND: Distribution Bus Module (P/N 514030) (2) TPH Fuse Battery Disconnect Positions64List RA: 1200A Low Voltage Battery Disconnect (LVBD) Contactor and Control Circuit (P/N 540808)65List RB: 1200A Manual Battery Disconnect Contactor with Local and Remote Alarm (P/N 540809)66List RC: 2000A Manual Battery Disconnect Contactor with Local and Remote Alarm (P/N 528446)67List RD: 2000A Low Voltage/Manual Battery Disconnect Contactor with Battery Current Monitoring (P/N 528447)68List RE: 2000A Low Voltage Battery Disconnect Contactor with Battery Current Monitoring (P/N 535064)69ACCESSORY DESCRIPTIONS70Relay Racks70Transition Plates to Mount Relay Rack on Top of GNB Absolyte IIP Batteries71Distribution Devices72GMT Load Distribution Fuse Block Assembly Kit (P/N 514432) (10) GMT Fuse Positions72GMT-Type Load Distribution Fuses73Replacement Alarm, Reference, and Control Fuses74TPH-Type Fuses75GJ/218-Type Circuit Breakers76Bullet Nose-Type Circuit Breakers and Bullet Nose-Type Fuseholders e/w TPS/TLS Fuses78Wiring Components81Load Distribution Wire Sizes and Lugs Selection81Input Battery Wire Sizes and Lugs Selection82Standard Crimp Lug Tables84Special Application Crimp Lug / Strap Combination Table85Wire Size and Lug Selection Tables for Load and Battery Connections to TPS/TLS Fuses and Bullet Nose-Type Circuit Breakers or Battery Branch Circuits86Wire Size and Lug Selection Tables for Load and Battery Connections to TPH Fuses and GJ/218-Type Circuit Breakers or Battery Branch Circuits88AC Input Branch Circuit Protection and Wire Size Selection90Relay Rack Frame Grounding Requirements90External Alarm, Reference, and Control Wire Sizes90Module Mounting Position Blank Cover Panel (P/N 540959)91Battery Charge Temperature Compensation Probe for Single Probe Digital Compensation (P/Ns 107021 and 106824)91Battery Charge Temperature Compensation Probe Concentrator for Multiple Probe Use (TXM)91Battery Temperature Probe Concentrator Kit (P/N 524570)91Analog Battery Temperature Probe (P/N 521262)92TXM Extension Cable (P/N 514153)92Battery Busbar Extension Kit (P/N 514713)92Battery Busbar Extension Kit (P/N 529143)92Lug Adapter Busbar for 250 Amp Bullet Nose Type Circuit Breaker (P/N 514717)93Lug Adapter Busbar Kit for 125-200 Amp Bullet Nose Type Circuit Breaker (P/N 534449)93Lug Adapter Busbar Kit for 250 Amp Bullet Nose Type Circuit Breaker (P/N 514714)93Bullet Distribution Assembly Lug Hardware Kit (P/N 520332)93LVD Contactor Bypass Kits (P/Ns 514910 and 514912)94Replacement Cables95Replacement Components98SPECIFICATIONS99PHYSICAL SIZE INFORMATION109Overall Dimensions109List 24 (Four Bus Row Cabinet)109List 23 (Three Bus Row Cabinet)110List 22 (Two Bus Row Cabinet)111List 21 (One Bus Row Cabinet)112List 93 (Battery Tray)113Optional Digital Battery Charge Temperature Compensation Probe (P/N 107021 and 106824)114Optional Analog Battery Temperature Probe (P/N 521262)114Electrical Connection Locations and Dimensions115Input Battery115Load Distribution119AC Input119External Alarm, Reference, and Control120RELATED DOCUMENTATION121BATTERY MANUFACTURER INFORMATION122Size: 5.8 MBPages: 123Language: EnglishOpen manual
User ManualTable of ContentsSYSTEM OVERVIEW1TABLE OF CONTENTS5ORDERING INFORMATION9List Options9List Options (Numbers)9List Options (Letters) (Distribution Bus Arrangements)11Accessory Options15LIST DESCRIPTIONS16List 1: Main Bay Common Equipment (Power and Distribution)16List 2: Supplemental Bay Common Equipment (Power and Distribution) (located next to Main Bay)17List 4: “Distribution Only” Option for Lists 2 or 518List 5: Supplemental Bay Common Equipment (Power and Distribution) (located away from Main Bay)18List 10: MCA (Standard Application)19List 11: MCA (Special Application)19List 12: MCA (Special Application)20List 13: MCA (Special Application)20List 21: One-Row Distribution Cabinet20List 22: Two-Row Distribution Cabinet21List 23: Three-Row Distribution Cabinet22List 24: Four-Row Distribution Cabinet22List 29: Top Shield for Distribution Cabinet23List 30: Module Mounting Assembly Interface Components23List 31: Field Expansion Kit: One (1) 8-Position Module Mounting Assembly24List 50: Rectifier Module (PCU)25List 60: DC-DC Converter Option Interface Component Kit25List 62: DC-DC Converter Module26List 71: Optional Audible Alarm and Alarm Termination Circuit Card26List 72: MCA Interface Modem Option26List 73: MCA Interface WinLink Software27List 74: MCA Interface Combination Modem/RS-232 Option27List 75: MCA Interface Ethernet Option: WinLink Compatible + Web Interface28List 76: MCA Interface Ethernet Option: WinLink Compatible + Web Interface + SNMP28List 77: MCA Interface Ethernet Option: WinLink Compatible + Web Interface + Battery Monitoring29List 78: MCA Interface Ethernet Option: WinLink Compatible + Web Interface + SNMP + Battery Monitoring29List 92: Battery Stand System30List 93: Battery Tray, Pre-Cabled30List AA: Distribution Bus Module (P/N 509840) (24) Fuse/Circuit Breaker System Positions33List AB: Distribution Bus Module (P/N 428316100) (3) GJ/218 Circuit Breaker System Positions34List AC: Distribution Bus Module (P/N 507198) (3) GJ/218 Circuit Breaker System Positions35List AD: Distribution Bus Module (P/N 509565) (8) GJ/218 Circuit Breaker System Positions (Upper Two Rows)36List AE: Distribution Bus Module (P/N 509648) (8) GJ/218 Circuit Breaker System Positions (Lower Two Rows)37List AG: Distribution Bus Module (P/N 514010) (2) TPH Fuse System Positions38List AH: Distribution Bus Module Ground Bar Assembly (P/N 500676) for Use with Up to (2) List AG, AJ, CG, or CJ39List AJ: Distribution Bus Module (P/N 520819) (2) TPH Fuse System Positions with Load Metering Shunts40List AK: Distribution Bus Module (P/N 520805) (24) Fuse/Circuit Breaker System Positions41List AL: Distribution Bus Module Ground Bar Assembly for Use with Up to (2) List AK42List AM: Distribution Bus Module (P/N 524632) (20) Fuse/Circuit Breaker System Positions (1) 3-Pole Input Disconnect Fuse/Circuit Breaker Position43List BA: Distribution Bus Module (P/N 520534) (12) Fuse/Circuit Breaker System Positions with LVD (8) Fuse/Circuit Breaker System Positions without LVD44List CA: Distribution Bus Module (P/N 509848) (20) Fuse/Circuit Breaker System Positions w/LVLD45List CB: Distribution Bus Module (P/N 513738) (3) GJ/218 Circuit Breaker System Positions w/LVLD46List CD: Distribution Bus Module (P/N 507200) (3) GJ/218 Circuit Breaker System Positions w/LVLD47List CE: Distribution Bus Module (P/N 509564) (8) GJ/218 Circuit Breaker System Positions w/LVLD (Upper Two Rows)48List CF: Distribution Bus Module (P/N 509647) (8) GJ/218 Circuit Breaker System Positions w/LVLD (Lower Two Rows)49List CG: Distribution Bus Module (P/N 514035) (2) TPH Distribution Fuse Positions w/LVLD50List CJ: Distribution Bus Module (P/N 520936) (2) TPH Distribution Fuse Positions with Load Metering Shunts and LVLD51List EA: Distribution Bus Module (P/N 509852) (16) Fuse/Circuit Breaker System Positions and (4) Fuse/Circuit Breaker Battery Disconnect Positions52List GB: Distribution Bus Module (P/N 513806) (8) Fuse/Circuit Breaker System Positions w/LVD and (1) TPH Fuse Battery Disconnect Position53List JA: Distribution Bus Module (Part No. 509906) (4) +24V Fuse/Circuit Breaker System Positions and (16) –48V Fuse/Circuit Breaker Subsystem Positions54List JB: Distribution Bus Module (Part No. 513808) (12) +24V Fuse/Circuit Breaker System Positions and (8) –48V Fuse/Circuit Breaker Subsystem Positions55List JC: Distribution Bus Module (Part No. 524403) (14) +24V Fuse/Circuit Breaker System Positions and (6) –48V Fuse/Circuit Breaker Subsystem Positions56List JD: Distribution Bus Module (Part No. 524788) (14) +24V Fuse/Circuit Breaker System Positions and (8) –48V Fuse/Circuit Breaker Subsystem Positions57List KA: Distribution Bus Module (Part No. 520507) (4) +24V Fuse/Circuit Breaker System Positions and (16) –48V Fuse/Circuit Breaker Subsystem Positions58List LB: Distribution Bus Module (Part No. 513807) (8) +24V Fuse/Circuit Breaker System Positions w/LVD and (8) –48V Fuse/Circuit Breaker Subsystem Positions59List LC: Distribution Bus Module (Part No. 514623) (12) +24V Fuse/Circuit Breaker System Positions w/LVD and (4) –48V Fuse/Circuit Breaker Subsystem Positions60List NA: Distribution Bus Module (P/N 514336) (20) Fuse/Circuit Breaker Battery Disconnect Positions61List NB: Distribution Bus Module (P/N 513809) (3) GJ/218 Circuit Breaker Battery Disconnect Positions62List NC: Distribution Bus Module (P/N 514025) (1) TPH Fuse Battery Disconnect Position63List ND: Distribution Bus Module (P/N 514030) (2) TPH Fuse Battery Disconnect Positions64List RA: 1200A Low Voltage Battery Disconnect (LVBD) Contactor and Control Circuit (P/N 540808)65List RB: 1200A Manual Battery Disconnect Contactor with Local and Remote Alarm (P/N 540809)66List RC: 2000A Manual Battery Disconnect Contactor with Local and Remote Alarm (P/N 528446)67List RD: 2000A Low Voltage/Manual Battery Disconnect Contactor with Battery Current Monitoring (P/N 528447)68List RE: 2000A Low Voltage Battery Disconnect Contactor with Battery Current Monitoring (P/N 535064)69ACCESSORY DESCRIPTIONS70Relay Racks70Transition Plates to Mount Relay Rack on Top of GNB Absolyte IIP Batteries71Distribution Devices72GMT Load Distribution Fuse Block Assembly Kit (P/N 514432) (10) GMT Fuse Positions72GMT-Type Load Distribution Fuses73Replacement Alarm, Reference, and Control Fuses74TPH-Type Fuses75GJ/218-Type Circuit Breakers76Bullet Nose-Type Circuit Breakers and Bullet Nose-Type Fuseholders e/w TPS/TLS Fuses78Wiring Components81Load Distribution Wire Sizes and Lugs Selection81Input Battery Wire Sizes and Lugs Selection82Standard Crimp Lug Tables84Special Application Crimp Lug / Strap Combination Table85Wire Size and Lug Selection Tables for Load and Battery Connections to TPS/TLS Fuses and Bullet Nose-Type Circuit Breakers or Battery Branch Circuits86Wire Size and Lug Selection Tables for Load and Battery Connections to TPH Fuses and GJ/218-Type Circuit Breakers or Battery Branch Circuits88AC Input Branch Circuit Protection and Wire Size Selection90Relay Rack Frame Grounding Requirements90External Alarm, Reference, and Control Wire Sizes90Module Mounting Position Blank Cover Panel (P/N 540959)91Battery Charge Temperature Compensation Probe for Single Probe Digital Compensation (P/Ns 107021 and 106824)91Battery Charge Temperature Compensation Probe Concentrator for Multiple Probe Use (TXM)91Battery Temperature Probe Concentrator Kit (P/N 524570)91Analog Battery Temperature Probe (P/N 521262)92TXM Extension Cable (P/N 514153)92Battery Busbar Extension Kit (P/N 514713)92Battery Busbar Extension Kit (P/N 529143)92Lug Adapter Busbar for 250 Amp Bullet Nose Type Circuit Breaker (P/N 514717)93Lug Adapter Busbar Kit for 125-200 Amp Bullet Nose Type Circuit Breaker (P/N 534449)93Lug Adapter Busbar Kit for 250 Amp Bullet Nose Type Circuit Breaker (P/N 514714)93Bullet Distribution Assembly Lug Hardware Kit (P/N 520332)93LVD Contactor Bypass Kits (P/Ns 514910 and 514912)94Replacement Cables95Replacement Components98SPECIFICATIONS99PHYSICAL SIZE INFORMATION109Overall Dimensions109List 24 (Four Bus Row Cabinet)109List 23 (Three Bus Row Cabinet)110List 22 (Two Bus Row Cabinet)111List 21 (One Bus Row Cabinet)112List 93 (Battery Tray)113Optional Digital Battery Charge Temperature Compensation Probe (P/N 107021 and 106824)114Optional Analog Battery Temperature Probe (P/N 521262)114Electrical Connection Locations and Dimensions115Input Battery115Load Distribution119AC Input119External Alarm, Reference, and Control120RELATED DOCUMENTATION121BATTERY MANUFACTURER INFORMATION122Size: 5.8 MBPages: 123Language: EnglishOpen manual