DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance A between the wall cabinets is between 600 mm and 680 mm, the
height B must be a minimum of 520 mm.
If the distance A between the wall cabinets is greater than the width of the
cooktop, the height B must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE
CATEGORY II2H3+
ELECTRIC SUPPLY: 230 V 50 Hz
Type of gas used
Type of
burner
Injector
marking
100/mm
Rated
heat
capacity
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure
mbar
min.
rat.
max.
NATURAL GAS
(Methane)
(Methane)
G20
large
medium
small
128
94
76
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17
20
25
LIQUID PETROLEUM
GAS
(Cylinder)
(Cylinder)
G30
large
medium
small
85
65
50
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
20
28-30
35
LIQUID PETROLEUM
GAS
(Cylinder)
(Cylinder)
G31
large
medium
small
85
65
50
3.00
1.65
1.00
214 g/h
118 g/h
71 g/h
0.60
0.35
0.30
25
37
45
Type of gas used
Appliance
model
Total rated heat
capacity kW
Total rated
consumption
Air required
for burning
m3/h
G20 20 mbar
4 gas
7.30
695 l/h
14.6
G30 28-30 mbar
4 gas
7.30
531 g/h
14.6
G31 37 mbar
4 gas
7.30
521 g/h