Chapter 8. Configuring DBU Options
61200275L1-1
TSU IQ+ User Manual
8-5
be identical. If using front panel entry, see the section Entering
Letters Using the Front Panel 
on page 9-6 
in the chapter System
Configuration 
for more information. This field is not available when
the PRI DBU card is installed.
Daily Lockout
Enable/disable the daily lockout specified by the fields
L
OCKOUT
S
TART
and
L
OCKOUT
E
ND
.
Lockout Start
Enter the hour that the daily lockout begins and dial backup is
disabled. This setting only applies if the
D
AILY
L
OCKOUT
parameter
is enabled. Choices are
0
to
23
.
Lockout End
Enter the hour that the daily lockout ends and dial backup is
reactivated (0 to 23). This setting only applies if the
D
AILY
L
OCKOUT
parameter is enabled.
Weekend Lock
If enabled, no backup will occur from midnight Friday to midnight
Sunday.
DBU CRITERIA
With Network Failure (WITH NETFAIL)
When enabled, the TSU IQ+ enters backup mode when network
failure is detected. The factory default setting is
E
NABLE
.
With No LMI
When enabled, the TSU IQ+ enters backup mode when a loss of
signaling from the frame relay switch is detected. The default
setting is
E
NABLE
.
With PVC Inactive
This option works in conjunction with the
DBU
ON
I
NACTIVE
option
in the PVC configuration table. The
W
ITH
PVC I
NACTIVE
option acts
as a master switch for auto DBU operation based on the PVC state.
If this option is set to
E
NABLED
, then each
DBU
ON
I
NACTIVE
option
applies. If this option is set to
D
ISABLE
, then each
DBU
ON
I
NACTIVE
option is disabled. See DBU on Inactive on page 7-7.