Grounding
312761B
Grounding
This product must be grounded. In the event of an elec-
trical short circuit, grounding reduces the risk of electric 
shock by providing an escape wire for the electric cur-
rent. This product is equipped with a chord having a 
grounding wire. A 3-blade grounding plug must be 
installed or the machine may be hard wired. The plug 
must be plugged into an outlet that is properly installed 
and grounded in accordance with all local codes and 
ordinances.
Improper installation of the grounding plug is able to 
result in a risk of electric shock. The wire with insulation 
having an outer surface that is green with or without yel-
low stripes is the grounding wire. Do not modify the plug 
provided; if it does not fit the outlet, have the proper out-
let installed by a qualified electrician. Only connect the 
product to an outlet having the same configuration as 
the plug. Do not use an adapter with this product.
Installation
Connect Electrical Cord
1.
Each machine comes with a permanent 10 ft power 
cable without a plug. If a permanent extension cable 
must be installed onto the existing cable or if an 
extension cord is necessary, be sure to use the 
appropriate gauge wire for the machine amperage. 
See the following table. 
Install Plug
2.
For machines that will not be hard-wired, install a 
3-blade 240V, 1-phase grounding plug onto 
cord (129). The machine must use a receptacle that 
accepts the plug on the product.
For machines that will be hard-wired, hard-wire 
the machine. The grounding wire must be used.
Machine may be hard-wired or installed using a 
plug.
Improper wiring may cause electric shock or other 
serious injury if work is not performed properly. Have 
a qualified electrician perform any electrical work. Be 
sure your installation complies with all National, State 
and Local safety and fire codes.
Number of Zones 
installed in Heat 
Control Box
Rating
(Amps)
Gauge (mm
2
) / 
Number of Wires
1
30
10 (2.59) / 3
2
30
10 (2.59) / 3
3
40
8 (3.26) / 3
4
40
8 (3.26) / 3
The equipment must be grounded. Grounding 
reduces the risk of static and electric shock by provid-
ing an escape wire for the electrical current due to 
static build up or in the event of a short circuit. 
Improper installation of the grounding plug is able to 
result in a risk of electric shock. The wire with insula-
tion having an outer surface that is green with or with-
out yellow stripes is the grounding wire.