Basic Configuration
1. Determine the necessary conversion operations 
to convert from the factory-supplied 
configuration to the desired configuration.
2. Perform the conversions required so the machine 
is properly configured for the desired country and 
gas (refer to Specific Conversion Procedures 
section):
How to Convert Gas Valve from Regulated to 
Unregulated
NOTE: Conversion from regulated to unregulated 
is only needed when regulated tumblers were 
ordered, but unregulated tumblers were needed.
How to Change Burner Orifice Size
How to Adjust Gas Valve Governor/Regulator
3. If applicable, peel off the appropriate country 
sticker (included with machine) and apply it to 
the serial plate over the existing country 
information.
4. If applicable, peel off the appropriate conversion 
sticker (included with machine) and apply it to 
the serial plate over the “ADJUSTED FOR 
______ GAS: ______” information.
5. Commission tumbler for use.
Figure 11 
Specific Conversion Procedures
How to Convert Gas Valve from Regulated to 
Unregulated
NOTE: Conversion from regulated to unregulated 
is only needed when regulated tumblers were 
ordered, but unregulated tumblers were needed.
Johnson G96 Gas Valve:
a. Disconnect electrical power from tumbler. 
Close gas shut-off valve to tumbler. Refer to 
b. Follow instructions in Conversion Kit, Part 
No. M400763 (Johnson Part No. Y71AA-5C).
NOTE: This kit does not contain any burner 
orifices.
c. Replace burner orifice(s) as per Table 1.
d. Commission tumbler for use.
WARNING
When converting the tumbler to a 
different gas or pressure, first verify that 
the supply inlet pressure is equipped with 
a pressure regulator (located ahead of the 
tumbler) that will maintain the gas supply 
at the inlet pressure specified.
W430
T103K
1
Gas Shut-Off Valve (Ahead of pressure tap)
2
Pressure Tap
3
Gas Shut-Off Valve (Shown in closed 
position)
SPECIFIED 
LOCAL INLET 
PRESSURE
3
2