Installing Steam Trap and Making 
Condensate Return Connections
The steam trap must be installed and the coil outlet 
connections must be connected to the condensate 
return lines. The following steps outline the procedure 
for installing the steam trap and connecting the 
condensate return lines. Refer to Figure 14 and 
Figure 15 for typical installations.
1. Use flexible lines between steam inlet solenoid 
and steam coils, as well as outlet between steam 
coil and traps.
2. If necessary, install a strainer to the end of each 
flexible hose.
3. Install a steam trap to each strainer.
IMPORTANT: Steam trap must be installed a 
minimum of 18 inches (457 mm) below the steam 
coil outlet connections.
4. Install a shut-off valve to each steam trap.
5. Connect to the condensate return lines.
6. For steam solenoid valve wiring connections, 
refer to Wiring Diagram supplied with tumble 
dryer.
Thermal Oil Prep
It is the responsibility of the customer to install 
appropriate coil and heating system for thermal oil 
prep models. Alliance Laundry Systems, LLC. is not 
responsible for the performance or safety of the 
customer installed thermal oil system. To ensure 
proper operation, refer to the Specifications and 
Dimensions section for the BTU input of equivalent 
steam models. Thermal oil systems that do not deliver 
appropriate BTUs will dry slower. For solenoid valve 
wiring connections, refer to the Wiring Diagram 
supplied with tumble dryer.
WARNING
All system components must have a 
125 psig (8.6 bar) working pressure. 
Shut-off valves must be installed 
upstream of the steam solenoid valve and 
downstream of each steam trap so 
components can be isolated for 
maintenance or emergency purposes. 
All components (solenoid valve, traps) 
must be supported to minimize loads on 
the tumble dryer steam coil connections.
W480R2