47
70420801 (EN)
Adjustments
Gas Burner Air Shutter
NOTE: Air inlet shutters on the burner must be 
adjusted so sufficient air is metered into the system 
for proper combustion and maximum efficiency. 
Before adjusting the inlet shutters, be sure that all 
lint is removed from lint compartments and lint 
screen.
Air shutter adjustment will vary from location to 
location and will depend on the vent system, number 
of units installed, make-up air and line gas pressure. 
Opening the shutter increases the amount of primary 
air supplied to the burner, while closing the shutter 
decreases the primary air supply. Adjust air shutter as 
follows:
Refer to Figure 16.
1. Remove the upper access panel and burner 
inspection hole plate.
2. Start the tumble dryer and check the flame 
pattern. If the flame pattern is straight up, 
insufficient air is flowing through the tumble 
dryer. A flame pattern that flares to the right and 
left indicates no air is flowing through the tumble 
dryer. Correct air and gas mixture is indicated if 
the flame pattern is primarily blue, with small 
yellow tips, and bends to the left of the heater 
section. Too little air is indicated if the flame is 
yellow, lazy and smoky. 
3. To adjust the air shutter, loosen air inlet shutter 
adjusting screw.
4. Open or close air shutter as necessary to obtain 
proper flame intensity.
5. After air shutter is adjusted for proper flame, 
tighten air shutter adjusting screw securely. 
Figure 16 
To reduce the risk of electric shock, fire, 
explosion, serious injury or death:
• Disconnect electric power to the tumble 
dryer before servicing.
• Close gas shut-off valve to gas tumble 
dryer before servicing.
• Close steam valve to steam tumble dryer 
before servicing.
• Never start the tumble dryer with any 
guards/panels removed.
• Whenever ground wires are removed 
during servicing, these ground wires 
must be reconnected to ensure that the 
tumble dryer is properly grounded.
W002R1
WARNING
T464I
1
Air Shutter Adjusting Screw
PROPER AIRFLOW
INSUFFICIENT AIRFLOW
NO AIRFLOW
1
1
1