 This dryer is internally grounded to neutral unless it was manufactured for sale in Canada. Grounding through 
the neutral link is prohibited for: (1) new branch circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas 
where local codes do not permit grounding through the neutral.
3
Electrical System Requirements
Electrical requirements for electric dryer
CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately fused 
circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit.
POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current.
3-WIRE POWER SUPPLY CORD KIT (not supplied)
OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R receptacle to be located so the power supply cord is accessible when the 
dryer is in the installed position.
GROUNDING CONNECTION - See “Grounding requirements” in Electrical Installation section.
The dryer MUST employ a 3-conductor power supply cord 
NEMA 10-30 type SRDT rated at 240 volt AC minimum, 
30 amp, with 3 open end spade lug connectors with 
upturned ends or closed loop connectors and marked 
for use with clothes dryers. For 3-wire cord connection 
instructions see ELECTRICAL CONNECTIONS FOR A 
3-WIRE SYSTEM.
4-WIRE POWER SUPPLY CORD KIT (not supplied)
The dryer MUST employ a 4-conductor power supply cord 
NEMA 14-30 type SRDT or ST (as required) rated at 240 
volt AC minimum, 30 amp, with 4 open end spade lug 
connectors with upturned ends or closed loop connectors 
and marked for use with clothes dryers. For 4-wire cord 
connection instructions see ELECTRICAL CONNECTIONS 
FOR A 4-WIRE SYSTEM.
Electrical requirements for gas dryer
CIRCUIT -  Individual, properly polarized and grounded 15 
amp. branch circuit fused with 15 amp. time delay fuse or 
circuit breaker.
POWER SUPPLY - 2-wire, with ground, 120 volt, single phase, 
60 Hz, Alternating Current. 
POWER SUPPLY CORD - The dryer is equipped with a 120 volt 
3-wire power cord. 
GROUNDING CONNECTION - See “Grounding requirements” 
in Electrical Installation section. 
Grounding type
Grounding type
wa
wall receptacl
ll receptacle
Po
Power cord with
wer cord with
3-prong 
3-prong  gr
grounded plug
ounded plug
Do not,
Do not, under
under
an
any cir
y circumstances,
cumstances,
cut,
cut, remo
remove
ve,
or b
or bypass th
ypass the
gr
grounding pr
ounding prong.
ong.
3-wire receptacle
(NEMA type 10-30R)
4-wire receptacle
(NEMA type 14-30R)
 Because of potentially inconsistent voltage capabilities, the use of this dryer with power created by gas powered gen-
erators, solar powered generators, wind powered generators or any other generator other than the local utility company is not 
recommended.
 Dryers manufactured for sale in Canada have factory-
installed, 4-wire power supply cord (NEMA 14-30R).