JAI 141MCL-RA Manual De Usuario

Descargar
Página de 52
 
CM-141MCL/PMCL/-RA / CB-141MCL/PMCL/-RA
 
 
 
9
   
5.2.2   CM-141
 
PMCL /-RA and CB-141
 
PMCL/-RA   
 
 
 
 
 
 
 
 
 
 
 
Important Note for PMCL version 
 
CM-141 PMCL/-RA and CB-141 PMCL/-RA cameras feature “Safe Power” circuit which is 
stipulated by the PoCL standard.  This circuit is used to verify the presence of camera and 
PoCL cable before the frame grabber provides power. 
 
 
5.3  DIP switch SW600 
This is for the selection of TTL or 75  ohm 
termination for trigger input. 
Factory default setting is TTL. 
When DIP switch SW600 is changed, at  first 
 remove the top cover.  The factory  default is 
 set two switches to OFF  position.  In order to 
 set 75 ohm, two  switches should be changed to 
 ON  position. 
 
         
                                                                             Fig.6.  SW-600 DIP switch 
 
 
 
 
 
 
 
 
 
 
Pin No 
I/O 
Name 
Note 
DC +12V 
 
13 
GND 
For # 26 pin 
14 
GND 
For # 1 pin 
26 
DC +12V 
 
7(+),20(-) 
I/O 
RXD 
Serial Com. 
8(-),21(+) 
TXD 
10(+),23(-) 
Reserve 
 
9(-),22(+) 
Trigger 
CC1 Ext. Trigger in 
6(-),19(+) 
TxOUT3 
Camera Link out 
4(-),17(+) 
TxOUT2 
3(-),16(+) 
TxOUT1 
2(-),15(+) 
TxOUT0 
5(-),18(+) 
TxClk 
Clock for CL 
Fig.5.  Mini-CL 
connector 
 
1
2
O
N
TTL
75 Ω