3
595-5657-04
SPECIFICATIONS
Range .....................Up to 30 ft. (9.1 m) 
[varies with surround-
ing temperature]
Sensing Angle ........Up to 150°
Sensor Capacity .....Up to 360 Watts (3.0 
A.) Maximum Tungsten 
Incandescent
Power
Requirements .........120 VAC, 60 Hz
Operating Modes ....TEST, AUTO and 
MANUAL OVERRIDE
Time Delay .............1, 5, 20 minutes
Sensitivity ...............Adjustable
D
ual
B
rite
®
 Timer ....Off, 3, 6 hours, Dusk-
to-Dawn
HeathCo LLC reserves the right to discon-
tinue products and to change specifications 
at any time without incurring any obligation 
to incorporate new features in products pre-
viously sold.
Black sensor 
wire to 
Black 
post wire
White sensor 
wire to 
White 
post wire
White sensor 
wire to 
White 
fixture wire
Green sensor 
wire to 
Green or 
bare fixture wire
Red sensor 
wire to 
Black 
fixture wire
Green sensor 
wire to 
Green or 
bare post wire
TESTING
Turn  on  the  circuit  breaker  and  light 
switch.
 Maximum Range
Maximum
Coverage Angle
Avoid aiming the control at:
•  
Pools  of  water  or  objects  that  change 
temperature rapidly, such as 
heating vents 
and air conditioners. These heat sources 
could cause false triggering.
•  Areas  where 
pets  or  traffic  may  trigger 
the control.
•  
Nearby large, light-colored objects reflect-
ing daylight may trigger the shut-off feature. 
Do not point other lights at the sensor.
Note:  Sensor has a 1 
1
/
2
 minute warm up pe-
riod before it will detect motion. When 
first turned on wait 1 
1
/
2
 minutes.
30 ft. 
(9.1 m)
5 ft.
(1.5 m)
150°
Least Sensitive
Most Sensitive
The  detector  is  less  sensitive  to  motion  di-
rectly towards it and more sensitive to across 
motion.
Sensor
Motion
Motion