The appliance, when installed, must be electrically grounded in ac-
cordance with local codes or, in the absence of local codes, with the 
National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, 
CSA C22.1, if an external electrical source is utilized.  This appli-
ance is equipped with a three-prong [grounding] plug for your 
protection against shock hazard and should be plugged directly 
into a properly grounded three-prong receptacle.  Do not cut or 
remove the grounding prong from this plug.  For an ungrounded 
receptacle, an adapter, which has two prongs and a wire for ground-
ing, can be purchased, plugged into the ungrounded receptacle and 
its wire connected to the receptacle mounting screw.  With this wire 
completing the ground, the appliance cord plug can be plugged into 
the adapter and be electrically grounded.  
CAUTION: Label all wires prior to disconnection when servicing 
controls.    Wiring  errors  can  cause  improper  and  dangerous 
operation.  Verify proper operation after servicing.  
Note:    For  testing  flame  sensor  circuit  use  a  micro-amp  meter  in 
series with sensor.  Minimum current should be 1 micro-amp dur-
ing operation.  Be careful as flame sensor is in the 115VAC circuit.  
If  current  is  below  1  micro-amp,  remove  sensor,  clean  with  light 
sandpaper and retest. 
Note: This heater is equipped with a remote bulb electronic thermistor 
control located down low at the back of the furnace. Sometimes due 
to field locations different air currents may effect the control sensing 
of the thermistor. This sensing bulb can be re-located if necessary to 
provided for better room air sensing and control. 
Replacement of Thermistor with 24 Volt Wall Thermostat
  1.  If furnace is installed, turn off gas supply and electric supply.
  2.  Remove casing front.
  3.  Remove black hose from front nipple on pressure switch.
  4.  Remove junction box cover (4 screws).
  5.  Please refer to wiring diagram for removal of the following 
wires.
  6.  Internal  Electronic  Thermostat/Temperature  Control 
Board
Attention!  No 24 volt wall thermostat wires are to be at-
tached to the internal electronic thermostat.
  7.  Control Board
A.  Remove white wire form screw marked W.
B.  Remove yellow wire from screw marked C.
C.  Remove red wire from screw marked R.
  8.  Route (2) wires from any 24 volt wall thermostat through the 
casing back of furnace to the screws marked W and R on the 
control board.
  9.  Replace junction box cover (4 screws).
  10.  Replace black hose onto front nipple on pressure switch.
  11.  Replacement  of  thermistor  with  24  volt  wall  thermostat  is 
completed.
CIRCULATING AIR BLOWER
WHT
FS
LS
RED
YEL
RED
BLK
1
PUR
PUR
INDUCER
BLOWER
BLU
BLU
6
5
3
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED
WITH A WIRE OF AT LEAST 105
° C TEMPERATURE RATING.
LIMIT SWITCH
SECONDARY
FIELD INSTALLED
THERMOSTAT
24 VOLT
115 VAC
SWITCH
LIMIT
3A FUSE
GND
BLACK
WHITE
ON/OFF
ROLLOUT
PRESSURE
SWITCH
R-8191
VALVE
GAS
TRANSFORMER
24 VAC
PRIMARY
115 VAC
COMMON
DISCONNECT INTEGRAL THERMOSTAT "R", "W", AND "C" LEADS AND ATTACH WALL THERMOSTAT AS SHOWN
R
W
5
6
PS
ROS
RED
GRN
ORG
7
8
9
ORG
ELECTRONIC
THERMOSTAT
INTEGRAL
WHT
YEL
RED
2
3
GR
Y
BRN
BRN
GV
GR
Y
24
V
WH
T
BLK
11
5
V
OPTIONAL WALL MOUNT THERMOSTAT
XFMR
ON/OFF
BLACK NEUTRAL
RIBBED
INSULATION
BLACK HOT
SMOOTH
INSULATION
CIRCULATING AIR
BLOWER MOTOR
RED LED
STATUS
LIGHT
IGN
HOT SURFACE
IGNITOR
POWER SWITCH
INDUCER MOTOR
FLAME SENSOR
COMBUSTION AIR
ROS = ROLLOUT LIMIT SWITCH
IGN = HOT SURFACE IGNITOR
PS = PRESSURE SWITCH
XFMR = TRANSFORMER
CORDSET 115 VAC
FS = FLAME SENSOR
GV = GAS VALVE
LS = LIMIT SWITCH
4
2
4
1
WIRING