Cal Flame BBQ11955P Manual De Usuario

Descargar
Página de 36
8
Installation / 
Assemb
ly
Power Burner
LTR50001100, Rev. A
www.calflamebbq.com
Natural Gas
Requirements
Always  check  the  rating  plate  to  make  sure  the  gas  supply  you  are 
hooking up to is the gas type the Power Burner is manufactured for.
IMPORTANT: Never connect the Power Burner to an unregulated gas 
supply.
The  installation  of  this  appliance  must  conform  with  local  codes  or, 
in  the  absence  of  local  codes,  to  the  national  fuel  gas  code,  ANSI 
Z223.1a-1998. Installation in Canada must be in accordance with the 
standard CAN/CGA-B149.2, Propane Installation Code.
A licensed contractor or local gas company representative must per-
form all natural gas connections.
Ensure that the service supplying the Power Burner is fitted with a shut 
off valve conveniently positioned near the appliance and giving ease 
of access.
The Power Burner must be isolated from the gas supply piping system 
by closing its individual manual shutoff valve during any pressure test-
ing of the gas supply piping system at test pressures equal to or less 
than 0.5 psi (3.5 kPa).
The Power Burner and its individual shutoff valve must be disconnected 
from the gas supply piping system during any pressure testing of that 
system at test pressure in excess of 0.5 psi (3.5 kPa).
The Power Burner for use with natural gas comes equipped with its 
own regulator that MUST NOT be removed. If this regulator needs to 
be replaced, use only the type specified by Cal Flame for this appli-
ance.
Connection
Slide the Power Burner forward to gain access to the regulator and 
1. 
gas connection point in the rear.
Connect a suitable flex connector to the NG regulator.
2. 
Check the controls to ensure all control valves are in the full OFF 
3. 
position.
Turn on the main gas supply and check all connections for leaks 
4. 
using soapy water as described in the leak testing procedure sec-
tion.