I. GENERAL 
INFORMATION 
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for 
use in the mitigation, treatment, or prevention of any disease or condition. 
There are different size units available, depending on the square footage of your home.  See chart below for 
determining your homes needs. 
Lamp Length 
Minimum 
Duct 
Width 
Volts 
Amps 
Hz 
Watts 
Max Air 
Temp 
°F 
Lamp Intensity at 1 
meter 
Recommended 
Max Sq. Feet 
12” 9 
120/240 
0.5 
60 
30 
150° 
37 
μW/cm
2
 
1500 
18” 14 
120/240 
0.5 
60 
30 
150° 
73 
μW/cm
2
 
2000 
28” 22 
120/240 
1.1 
60 
60 
150° 
105 
μW/cm
2
 
3000 
WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power 
OFF and have units unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to 
direct UVC light from any source. 
II. INSTALLATION 
1.  Determine a suitable location on either the supply or 
return for the unit as shown in Figure 1.  The unit must be 
mounted at least 3 feet from any flex duct type material. 
NOTE:    Unit can only be mounted in a vertical position as 
noted on inside cover label.
 
2.  Apply mounting template to air duct as shown in Figure 2. 
3.  Drill 1/8” diameter mounting holes at positions indicated 
on template. (See Figure 2) 
4.  Using a 2” hole saw, drill out lamp hole as shown on 
template. (See Figure 2) 
5.  Drill a 7/8” inspection hole as shown on template. (See 
Figure 2) 
6. Remove 
template. 
7.  Mount unit to duct using the 4 supplied sheet metal 
screws. (See Figure 3) 
 
Figure 2
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause
permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum.
Avoid touching the glass portion of the lamp with your hands. 