Lennox International Inc. 021 Manual De Usuario
Page 2
EDA 01/06
WARNING
This cased product contains fiberglass wool. Dis-
turbing the insulation during installation, mainte-
nance, or repair will expose you to fiberglass wool
dust. Breathing this may cause lung cancer. (Fiber-
glass wool is known to the State of California to
cause cancer.)
turbing the insulation during installation, mainte-
nance, or repair will expose you to fiberglass wool
dust. Breathing this may cause lung cancer. (Fiber-
glass wool is known to the State of California to
cause cancer.)
Fiberglass wool may also cause respiratory, skin,
and eye irritation.
and eye irritation.
To reduce exposure to this substance or for further
information, consult material safety data sheets
available from address shown below, or contact
your supervisor.
information, consult material safety data sheets
available from address shown below, or contact
your supervisor.
Lennox Industries Inc.
P.O. Box 799900
Dallas, TX 75379−9900
P.O. Box 799900
Dallas, TX 75379−9900
WARNING
Risk of explosion or fire. Can cause
injury or death. Recover all refrigerant
to relieve pressure before opening the
system.
injury or death. Recover all refrigerant
to relieve pressure before opening the
system.
IMPORTANT
The Clean Air Act of 1990 bans the intentional vent-
ing of refrigerant (CFC’s, HFC’s, and HCFC’s) as of
July 1, 1992. Approved methods of recovery, recycl-
ing or reclaiming must be followed. Fines and/or in-
carceration may be levied for noncompliance.
ing of refrigerant (CFC’s, HFC’s, and HCFC’s) as of
July 1, 1992. Approved methods of recovery, recycl-
ing or reclaiming must be followed. Fines and/or in-
carceration may be levied for noncompliance.
Unit Dimensions
EDA Model Dimensions − Inches (mm)
11/16 (17)
Dimension
EDA−024B
EDA−036C
EDA−060D
A
17−1/2 (445)
21 (533)
24−1/2 (622)
B
12−1/4 (311)
12−1/4 (311)
14 (356)
D
OUTLET
AIR
C
16−1/8 (422)
19−5/8 (498)
23−1/8 (587)
D
AIR
OPENING
D
16−1/8 (422)
19-5/8 (498)
23−1/8 (587)
11/16
20−3/4
11/16
E
1−3/8 (35)
3−1/8 (79)
4−7/8 (124)
11/16
(17)
20−3/4
(527)
11/16
(17)
F
3−1/8 (79)
4−7/8 (124)
6−5/8 (168)
G
3 (76)
3−1/4 (83)
4−3/4 (121)
11/16 (17)
1−7/16 (37)
20−1/8
(511)
22−1/4
(565)
11/16 (17)
INLET AIR OPENING
INLET AIR OPENING
9−1/2
(241)
(241)
11/16 (17)
C
B
A
E
G
F
1−3/4
(44)
11/16 (17)
1
(25)
2−1/2
(64)
Check/Flow Restrictor
to Vapor Line Tee
to Vapor Line Tee
Liquid Line
From Outdoor
Unit
From Outdoor
Unit
Liquid Line to
Indoor TXV
Indoor TXV
Electrical
Inlet
Inlet
To Charge Compensator
side connection
side connection