Installation Recommendations and Options
SUPPLY
RETURN
AIR HANDLER
TrueDRY
M33150
SEPARATE
RETURN
BACKDRAFT
DAMPER
(OPTIONAL)
GRAVITY DAMPER
A
Dedicated Return to Main Supply
SUPPLY
RETURN
AIR HANDLER
TrueDRY
M27324
BACKDRAFT
DAMPER
B
Main Return to Main Supply
SUPPLY
RETURN
AIR HANDLER
TrueDRY
M27325
C
Main Return to Main Return
TrueDRY
M33152
SEPARATE
RETURN
SUPPLY
D
Dedicated Return to Main Return
Ideal when…
•  Access to a dedicated central return for
TrueDRY DR65 is available.
•  Combined with A/C operation; requires
backdraft damper on the exhaust port to 
minimize backdraft when TrueDRY DR65 
is not on but A/C is.
•  Providing dry air to a specific area with
an optional 20% open gravity damper on 
TrueDRY DR65 supply.
Ideal when…
•  Running TrueDRY DR65 when not
running A/C. Requires damper on the 
exhaust port to minimize backdraft when 
TrueDRY DR65 is not on but A/C is.
•  Access to a dedicated central return for
TrueDRY DR65 is not available.
•  System fan should run with dehumidifier
for best results.
Ideal when…
•  TrueDRY DR65 will not be ducted to a
forced air HVAC system.
Ideal when…
•  Running TrueDRY DR65 with A/C
operation.
•  System fan must run with dehumidifier.
•  Minimizing discharge air temperature
(DAT) increase is preferred.
•  Access to a dedicated central return for
TrueDRY DR65 is not available.