Chamberlain 459950 Manual De Usuario

Descargar
Página de 88
17
INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door, at a minimum 
height of 5 feet (1.5 m) where small children cannot reach, 
away from moving parts of door and door hardware. 
If installing into drywall, drill 5/32" holes and use the 
anchors provided. For pre-wired installations (as in new 
home construction), it may be mounted to a single gang 
box (Figure 2).
NOTE: The functional temperature range of the door 
control is between -4° F (-20° C) and 122° F (50° C). 
Scroll speed of display is slower at lower temperatures 
although the door control remains fully functional.
CAUTION: Continuous exposure of the door control to 
temperatures below -22° F (-30° C) may damage the LCD 
screen.
1.   Strip 7/16" (11 mm) of insulation from one end of bell 
wire and connect to the two screw terminals on back of 
door control by color: white wire to W (2) and white/red 
wire to the R (1).
2.   Remove cover by gently prying at slot in top of the 
cover with a small fl at head screwdriver. Fasten with 
6ABx1-1/4" self-tapping screws (drywall installation) or 
6-32x1" machine screws (into gang box) as follows:
 
•   Install bottom screw, allowing 1/8" (3 mm) to 
protrude above wall surface.
 
•   Position bottom of door control on screw head and 
slide down to secure. Adjust screw for snug fi t.
 
•   Drill and install top screw with care to avoid cracking 
plastic housing.
 DO NOT overtighten.
 
•   Insert top tabs and snap on cover.
3.   (For standard installation only)
 Run bell wire up wall 
and across ceiling to motor unit. Use insulated staples 
to secure wire in several places. DO NOT pierce wire 
with a staple, creating a short or open circuit. 
4.   Strip 7/16" (11 mm) of insulation from end of bell wire. 
Connect bell wire to the quick-connect terminals as 
follows: white to white and white/red to red.
5.  Position the antenna wire as shown.
6.   Use tacks or staples to permanently attach entrapment 
warning label to wall near door control, and manual 
release/safety reverse test label in a prominent location 
on inside of garage door.
NOTE: DO NOT connect power and operate opener at 
this time. The trolley will travel to the full open position but 
will not return to the close position until the sensor beam 
is connected and properly aligned.
To prevent possible SERIOUS INJURY or DEATH from 
electrocution:
•  Disconnect ALL electric and battery power BEFORE 
performing ANY service or maintenance.
• Connect ONLY to 24 VOLT low voltage wires. 
To prevent possible SERIOUS INJURY or DEATH from 
a closing garage door:
•  Install door control within sight of garage door, out 
of reach of children at a minimum height of 5 feet 
(1.5 m), and away from ALL moving parts of door.
•  NEVER permit children to operate or play with door 
control push buttons or remote controls.
•  Activate door ONLY when it can be seen clearly, is 
properly adjusted, and there are no obstructions to 
door travel.
•  ALWAYS keep garage door in sight until completely 
closed. NEVER permit anyone to cross path of 
closing garage door.
Terminal 
 Screws
Top
Mounting
Hole
Bell 
 Wire
(BACK VIEW)
Bottom  
Mounting 
 Hole
Drywall Anchors
Push Bar 
Cover
To Replace 
Insert Top 
Tabs First
24 Volt 
Bell Wire
HARDWARE SHOWN ACTUAL SIZE
Screw 6ABx1-1/4"
(standard installation)
Insulated Staples
Screw 6-32x1" (pre-wired)
Outside Keylock Accessory Connections
To opener quick-connect terminals: white to white; 
white/red to red.
Door Control Connections
Strip wire 7/16" (11 mm)
To insert or release wire, push 
 in tab with screwdriver tip
Red White Grey
Figure 1
Figure 2
REMOVE & REPLACE COVER
PRE-WIRED 
INSTALLATION