Without a properly installed safety reversal system, 
persons (particularly small children) could be 
SERIOUSLY INJURED or KILLED by a closing garage 
door. 
•  Safety reversal system MUST be tested every month.
•  After ANY adjustments are made, the safety reversal 
system MUST be tested. Door MUST reverse on 
contact with 1-1/2" high (3.8 cm) object (or 2x4 laid 
fl at) on the fl oor.
ADJUSTMENT STEP 3
Test the Safety Reversal System
TEST
•   With the door fully open, place a 1-1/2" (3.8 cm) board 
(or a 2x4 laid fl at) on the fl oor, centered under the 
garage door.
•   Operate the door in the down direction. The door must 
reverse on striking the obstruction.
ADJUST
•   If the door stops on the obstruction, it is not traveling 
far enough in the down direction. Complete Adjustment 
Steps 1 and 2 Program the Travel Limits and Set the 
Force.
  
NOTE: 
On a sectional door, make sure limit adjustments 
do not force the door arm beyond a straight up and 
down position. See Figure 3, page 26.
•  Repeat the test.
•   When the door reverses on the 1-1/2" (3.8 cm) board 
(or 2x4 laid fl at), remove the obstruction and run the 
opener through 3 or 4 complete travel cycles to test 
adjustment.
•   If the unit continues to fail the Safety Reverse Test, call 
for a trained door systems technician.
IMPORTANT SAFETY CHECK:
Test the Safety Reverse System after:
•   Each adjustment of door arm length, limits, or force 
controls.
•    Any repair to or adjustment of the garage door 
(including springs and hardware).
•  Any repair to or buckling of the garage fl oor.
•  Any repair to or adjustment of the opener.
ADJUSTMENT STEP 4
Test The Protector System
®
•   Press the remote control push button to open the door.
•   Place the opener carton in the path of the door.
•   Press the remote control push button to close the door. 
The door will not move more than 1" (2.5 cm), and the 
opener lights will fl ash.
The garage door opener will not close from a remote if the 
indicator light in either sensor is off (alerting you to the 
fact that the sensor is misaligned or obstructed).
If the opener closes the door when the safety reversing 
sensor is obstructed (and the sensors are no more 
than 6" (15 cm) above the fl oor), call for a trained door 
systems technician.
Without a properly installed safety reversing sensor, 
persons (particularly small children) could be 
SERIOUSLY INJURED or KILLED by a closing garage 
door. 
1-1/2" (3.8 cm) board 
(or a 2x4 laid fl at)
Safety Reversing Sensor
Safety Reversing Sensor