Chamberlain 459950 Manual De Usuario

Descargar
Página de 88
35
Having a Problem? (Troubleshooting)
1.   My door will not close and the light bulbs blink on 
my motor unit: The safety reversing sensor must be 
connected and aligned correctly before the garage door 
opener will move in the down direction.
 
•   Verify the Safety Reversing Sensors are properly 
installed, aligned and free of any obstructions. 
Refer to Installation Step 11: Install The Protector 
System
®
.
 
•   Check diagnostic LED for fl ashes on the motor unit 
then refer to the Diagnostic Chart on the following 
page.
2.  My remotes will not activate the door:
 
•   Verify your Smart Control Panel
®
 is not blinking. If 
it is blinking, deactivate the Lock Mode following 
the instructions for Using the Wall-Mounted Door 
Control.
 
•   Reprogram remotes following the programming 
instructions. Refer to Programming. 
 
•   If remote will still not activate your door, check 
diagnostic LED for fl ashes on motor unit then refer 
to Diagnostic Chart on the following page.
3.   My door reverses for no apparent reason: Repeat 
safety reverse test after adjustments to force or travel 
limits. The need for occasional adjustment for the force 
and limit settings is normal. Weather conditions in 
particular can affect door travel.
 
•   Manually check door for balance or any binding 
problems. 
 • 
Refer 
to 
Adjustment Step 2, Set the Force.
4.   My door reverses for no apparent reason after fully 
closing and touching the fl oor: Repeat safety reverse 
test after adjustments to force or travel limits. The 
need for occasional adjustment for the force and limit 
settings is normal. Weather conditions in particular can 
affect door travel.
 • 
 
Refer 
to 
Adjustment Step 1, Program the Travel 
Limits.
5.  My lights will not turn off when door is open:
 
•   The garage door opener is equipped with a security 
light feature. This feature activates the light on 
when the safety reversing sensor beam has been 
obstructed. Refer to Operation section; Using the 
Wall-Mounted Door Control, Light Feature.
6.  My motor unit hums briefl y:
 
•   First verify that the trolley is against the stop bolt.
 
•   Release the door from the opener by pulling the 
Emergency Release Rope.
 
•   Manually bring the door to a closed position.
 
•   Loosen the belt by adjusting the outer nut 4 to 5 
turns. This relieves the tension.
 
•   Run the motor unit from the remote control or door 
control. The trolley should travel towards the door 
and stop. If the trolley re-engages with the door, pull 
the Emergency Release Rope to disengage.
 
•   Re-Tighten the outer nut until the trolley spring is 
approximately 1-1/4" (3.18 cm) in length.
 
•   If the trolley does not move away from the bolt, 
repeat the steps above.
7.  If battery status LED is not lit properly:
 
•  Check battery connections.
8.  My garage door opener beeps:
  •   A solid LED with beep, sounding approximately every 
2 seconds, indicates the motor unit is activating the 
door and is operating off of the battery
.
  •   A fl ashing LED with beep, sounding every 30 
seconds, indicates battery is low.
 
•   If a red LED remains on when the power is restored, 
and is accompanied by a beep sounding every 30 
seconds, replace the battery.
Trolley
1-1/4"
(3.18 cm)
Diagnostics
Located On
Motor Unit
Sending Eye Safety Reversing 
Sensor (Amber Indicator Light)
Receiving Eye Safety Reversing 
Sensor (Green Indicator Light)
Bell Wire
Safety Reversing Sensor
“Learn”
Button 
LED or
  
Diagnostic 
LED