CFM Corporation A132 Manual De Usuario

Descargar
Página de 32
7
Gas Fireplace Insert
10002964
CFM106
Typical Gas Line Connection
9-29-00
1/2” Gas Supply
1/2” x 3/8” Reducer
3/8” Nipple
3/8” x 3/8” Shut 
Off Valve
3/8” Nipple
3/8” Union
3/8” Nipple
CFM106
Fig. 4  Typical gas line installation.
When using copper or flex connector, use only 
approved fittings. Always provide a union when 
using black iron pipe so the gas line can be easily 
disconnected for burner or fan servicing. See gas 
specifications for pressure details and ratings. 
NOTE:  If flex connector is used, it must be kept inside 
of the heater.
Gas Supply Pressures
This heater must be isolated from the gas supply piping 
system by closing its individual manual shut-off valve 
during any pressure equal to or less than 1/2 psig 
(3.45kPa).
The heater and its individual shut-off valve must be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in 
excess of 1/2 psig (3.45kPa).
Installation of Remote Switch 
for RN/RP Gas Valves
1.  Thread wire through gas inlet opening on the right 
side of fireplace. Do not cut wire or insulation on 
metal edges.
2.  Slide switch assembly from the back, between sub-
frame and trim, then fasten the screw. (Fig. 5)
3.  For left side installation reverse switch position in 
bracket and repeat Step 2. (Fig. 6)
4.  Connect wiring to gas valve (Fig. 7a,b) and switch.
������
������
�����
Trim Screw
Wiring from 
Millivolt Gas 
Valve
On/Off Switch Assembly
FP1657
Fig. 5  Install switch between subframe and trim.
������
����������������
�����
Trim Top
Trim Left Side
Bracket Switch
Trim 
Screw
Wiring 
from 
Millivolt 
Gas 
Valve
On/Off 
Switch 
Assembly
FP1657
Fig. 6  Left side switch installation.
TPTH
TH
TP
FP1218a
Remote switch
wiring - rocker
1/03
FP1218a
Fig. 7b  ON/OFF switch wiring.
PILO
T
THTP
TP
TH
FP382a
REMOTE SWITCH WIRING - NVC
1/03
SIT Valve
Thermopile
FP382a
Fig. 7a  On/Off switch or millivolt thermostat.
CAUTION: Do not wire millivolt remote wall 
switch for gas fireplace to a 120 V power 
supply.
Adjustment of Leveling Bar
(If Required)
1.  Determine height of adjustment.
2.  Loosen the four (4) screws. (Fig. 8)
3.  Set bar at proper height and tighten the screws.
4.  Add the two (2) extra screws to prevent any move-
ment.
NOTE: Leveling bar only applies to A132.