Monessen Hearth CFX24 Manual De Usuario

Descargar
Página de 36
20
CFX Vent Free Fireplace System
20301726
LOG PLACEMENT
Before you begin — This unit is supplied with a set of three ceramic fiber logs. Do not handle these 
logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After 
handling logs, wash your hands gently with soap and water to remove any traces of fibers.
PROPER INSTALLATION SEQUENCE 
(CFX24) 
Figure 18 
1.  Install the rear log (#3) on back of burner.
2.  Install the right log (#1) on burner pins on right side of 
burner. 
3.  Install the left log (#2) on burner pins on left side of 
burner.
LG588 
CFX24 logs
Figure 18 - 
Log Placement CFX24
Rear Log 
#3
Left Log 
#2
Right Log #1
Burner Pins
Burner 
Pins
LG588
W
ARNING
The  positioning  of  the  logs  is  critical  to 
the safe and clean operation of this heater. 
Sooting and other problems may result if the 
logs are not properly and firmly positioned 
in the appliance. Never add additional logs 
or  embellishments  such  as  pine  cones, 
vermiculite or rock wool to the heater.
W
ARNING
Failure to position the parts in accordance 
with these diagrams or failure to use only 
parts specifically approved with this heater 
may result in property damage or personal 
injury.
CAUTION
DO NOT sprinkle volcanic rock on the logs 
or around the pilot or the main burner. This 
may  cause  sooting.  Only  place  volcanic 
rock on the floor of the fireplace.
During initial operation of the new heater, 
burning logs will give off a paper burning 
smell  and  orange  flames  will  be  present. 
Simply open the windows for a few hours 
to vent the odor.